DC ELECTRICAL CHARACTERISTICS FOR THE UT54ACTS08E7
( VDD = 3.0V to 5.5V; VSS = 0V6; -55C < TC < +125C)
SYMBOL
DESCRIPTION
VIL
Low-level input voltage 1
CONDITION
VIH
High-level input voltage 1
IIN
Input leakage current
VIN = VDD or VSS
VOL Low-level output voltage 3
IOL = 6mA
IOL = 8mA
VOH High-level output voltage 3
IOH = -6mA
IOH= -8mA
IOS
Short-circuit output current 2 ,4 VO = VDD and VSS
VDD
MIN
3.0V
5.5V
3.0V
2.0
5.5V
2.75
5.5V
-1
3.0V
4.5V
3.0V
2.4
4.5V
3.15
3.0V
-100
5.5V
-200
MAX
0.8
0.8
UNIT
V
V
1
A
0.4
V
0.4
V
V
V
100
mA
200
IOL
Low level output current
VIN = VDD or VSS
3.0V
6
mA
VOL = 0.4V
5.5V
8
IOH
High level output current
Ptotal Power dissipation 2, 8, ,9
VIN = VDD or VSS
VOH = VDD-0.4V
CL = 50pF
IDDQ
IDDQ
CIN
COUT
Quiescent Supply Current
Quiescent Supply Current Delta
Input capacitance 5
Output capacitance 5
VIN = VDD or VSS
For input under test
VIN = VDD - 2.1V
For all other inputs
VIN = VDD or VSS
= 1MHz
= 1MHz
3.0V
-6
5.5V
-8
5.5V
3.0V
5.5V
5.5V
mA
1.8
mW/
MHz
0.72
10
A
1.6
mA
0V
15
pF
0V
15
pF
Notes:
1. Functional tests are conducted in accordance with MIL-STD-883 with the following input test conditions: VIH = VIH(min) + 20%, - 0%; VIL = VIL(max) + 0%, - 50%,
as specified herein, for TTL, CMOS, or Schmitt compatible inputs. Devices may be tested using any input voltage within the above specified range, but are guaranteed
to VIH(min) and VIL(max).
2. Supplied as a design limit but not guaranteed or tested.
3. Per MIL-PRF-38535, for current density 5.0E5 amps/cm2, the maximum product of load capacitance (per output buffer) times frequency should not exceed 3,765pF/
MHz.
4. Not more than one output may be shorted at a time for maximum duration of one second.
5. Capacitance measured for initial qualification and when design changes may affect the value. Capacitance is measured between the designated terminal and VSS at
frequency of 1MHz and a signal amplitude of 50mV rms maximum.
6. Maximum allowable relative shift equals 50mV.
7. All specifications valid for radiation dose 1E6 rads(Si) per MIL-STD-883 Method 1019.
8. Power does not include power contribution of any TTL output sink current
9. Power dissipation specified per switching output.
6
 