3.1.9 Command Block Pointer Register (Read/Write) - Register 8
This register contains the location to start the Command Blocks. After execution begins, this register is automatically updated with
the address of the next block.
Bit
Number
15-0
Mnemonic
CBA(15:0)
Description
Command Block Address. These bits indicate the starting location of the Command Block.
3.1.10 BC Command Block Initialization Count Register (Read/Write)-Register 10
This register contains the number of command blocks that will be initialized when using the auto-initialize feature. If 0000 (hex)
is written into this register, then NO blocks will be set up. Because each Command Block requires eight contiguous memory locations,
the largest value allowed in this register is 1FFF (hex). If a larger value is written into this register, the SBC ignores the three most
significant bits.
Bit
Number
15-0
Mnemonic
CBC(15:0)
Description
Command Block Count. These bits indicate the number of Command Blocks set up during
auto-initialization.