DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

SP720 View Datasheet(PDF) - Littelfuse, Inc

Part Name
Description
Manufacturer
SP720 Datasheet PDF : 6 Pages
1 2 3 4 5 6
TVS Diode Arrays
Electronic Protection Array for ESD and Overvoltage Protection
SP720
Peak Transient Current Capability of the SP720
The peak transient current capability rises sharply as the width of the
current pulse narrows. Destructive testing was done to fully evaluate the
SP720’s ability to withstand a wide range of transient current pulses. The
circuit used to generate current pulses is shown in Figure 5.
The test circuit of Figure 5 is shown with a positive pulse input. For a
negative pulse input, the (-) current pulse input goes to an SP720 ‘IN’
input pin and the (+) current pulse input goes to the SP720 V- pin. The
V+ to V- supply of the SP720 must be allowed to float. (i.e., It is not tied
to the ground reference of the current pulse generator.) Figure 6 shows
the point of overstress as defined by increased leakage in excess of the
data sheet published limits.
The maximum peak input current capability is dependent on the V+ to V-
voltage supply level, improving as the supply voltage is reduced. Values
of 0, 5, 15 and 30 voltages are shown. The safe operating range of the
transient peak current should be limited to no more than 75% of the
measured overstress level for any given pulse width as shown in Figure 6.
When adjacent input pins are paralleled, the sustained peak current
capability is increased to nearly twice that of a single pin. For compari-
son, tests were run using dual pin combinations 1+2, 3+4, 5+6, 7+9,
10+11, 12+13 and 14+15.
The overstress curve is shown in Figure 6 for a 15V supply condition. The
dual pins are capable of 10A peak current for a 10µs pulse and 4A peak
current for a 1ms pulse. The complete for single pulse peak current vs.
pulse width time ranging up to 1 second are shown in Figure 6.
VARIABLETIME DURATION
+
R1
CURRENT PULSE GENERATOR
VG
-
CURRENT
SENSE
(-)
(+)
1 IN
V+ 16
2 IN
IN 15
VOLTAGE
PROBE
3 IN
IN 14
4 IN
IN 13
SP720
5 IN
IN 12
6 IN
IN 11
+
C1 -
7 IN
IN 10
R1 ~ 10TYPICAL
8 V-
IN 9
VG ADJ. 10V/A TYPICAL
C1 ~ 100µF
5
FIGURE 5. TYPICAL SP720 PEAK CURRENT TEST CIRCUIT
WITH A VARIABLEPULSE WIDTH INPUT
10
9
8
CAUTION: SAFE OPERATING CONDITIONS LIMIT
THE MAXIMUM PEAK CURRENT FOR A GIVEN
7
PULSE WIDTH TO BE NO GREATER THAN 75%
OF THE VALUES SHOWN ON EACH CURVE.
6
SINGLE PIN STRESS CURVES
DUAL PIN STRESS CURVE
5
4
3
2
1
0
0.001
0.01
0V
5V
30V
V+ TO V- SUPPLY
0.1
1
10
PULSE WIDTH TIME (ms)
15V
15V
100
1000
FIGURE 6. SP720 TYPICAL SINGLE PULSE PEAK CURRENT CURVES SHOWING THE MEASURED POINT OF OVER-STRESS IN
AMPERES vs PULSE TIME IN MILLISECONDS (TA = 25oC)
www.littelfuse.com
231
 

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]