Test Circuit
LA5606N
Function Table
Unit (capacitance: F)
The following table indicates conditions for operation with VIN1 ≥ VIN2 ≥ VIN3 (VIN1 ≥ 11 V, VIN2 ≥ 6 V and VIN3 ≥ 4 V).
EN1, EN2, EN3
H
L
VO1, VO2/VO3, VO4
L
H
1. Within the table of EN “H” indicates an H level and “L” indicates an L level.
2. In the table of VO “H” indicates an output on voltage while “L” indicates an output off voltage.
3. All output voltages corresponding to all EN locations are controlled independently.
(EN1 →VO1, EN2 → VO2 and VO3 , EN3 → VO4)
4. When EN is open, VO is at the H level.
EN (On/Off Control) Input Equivalent Block Diagram
VO1 (VO4)
VO2 and VO3
Unit (resistance: Ω)
No. 4370-5/6