C161K
C161O
Operating Conditions
The following operating conditions must not be exceeded in order to ensure correct
operation of the C161K/O. All parameters specified in the following sections refer to
these operating conditions, unless otherwise noticed.
Table 8
Operating Condition Parameters
Parameter
Symbol Limit Values Unit Notes
min.
max.
Standard
VDD
4.5
5.5
digital supply voltage
(5 V versions)
2.51)
5.5
V Active mode,
fCPUmax = 25 MHz
V Power Down mode
Reduced
VDD
3.0
3.6
digital supply voltage
(3 V versions)
2.51)
3.6
V Active mode,
fCPUmax = 20 MHz
V Power Down mode
Digital ground voltage
VSS
0
V Reference voltage
Overload current
IOV
–
±5
mA Per pin2)3)
Absolute sum of overload Σ|IOV| –
50
mA 3)
currents
External Load
Capacitance
CL
–
100
pF –
Ambient temperature
TA
0
70
-40
85
°C SAB-C161K/O …
°C SAF-C161K/O …
-40
125
°C SAK-C161K/O …
1) Output voltages and output currents will be reduced when VDD leaves the range defined for active mode.
2) Overload conditions occur if the standard operatings conditions are exceeded, i.e. the voltage on any pin
exceeds the specified range (i.e. VOV > VDD + 0.5 V or VOV < VSS - 0.5 V). The absolute sum of input overload
currents on all pins may not exceed 50 mA. The supply voltage must remain within the specified limits.
Proper operation is not guaranteed if overload conditions occur on functional pins such as XTAL1, RD, WR,
etc.
3) Not 100% tested, guaranteed by design and characterization.
Data Sheet
29
V2.0, 2001-01