Auxiliary Meter Specifications ± (% of reading + % of range)
Function
Range
Frequency
Temperature[2], ºC 600.0 ºC
Temperature[2], ºF
6000 ºC
600.0 ºF
AC Current[3]
6000 ºF
60.00 A
50 Hz – 1 kHz
600.0 A
50 Hz – 1 kHz
1 year Tcal ± 5 ºC
0.3 + 0.08
0.3 + 0.08
0.3 + 0.08
0.3 + 0.08
1.0 + 0.2
1.0 + 0.2
Measurement Characteristics
Full scale reading
DC voltage, True RMS AC voltage
Continuity
6,000-count
Maximum input voltage, 600 Vrms CAT II, 300 Vrms CAT III
DC coupled input coupling
Beeper < 60 W in 600 W range
Data Logger
Source
Range
Record size
Time span
Time reference
Record method
Digital multimeter measurements
10 divisions
Up to 2000 data points (with option 001)
Auto range 150 seconds to 20 days
Time from start
Selectable minimum, maximum and average
Display System
Display
Resolution
Control
Built-in help system
Real-time clock
4.5-inch diagonal color CSTN LCD
320 x 240 pixels
Contrast control, infinite persistance on/off
Functional help displayed by pressing help button
Time and date (user-adjustable)
Storage
Save/Recall (non-volatile)
Up to 10 setups and traces
[2] U1586B temperature module is needed to make measurements and is available as option.