1
BIPHASE IN
DATA
P
t20a
MES ERR
BIPHASE IN
MES ERR
RCV CMD
1
P
XMIT CMD P
t20b
Figure 20. Message Error
SYMBOL
PARAMETER
* t20a
Data word parity bit to MES ERR
assertion 1
* t20b
Command word parity bit to MES ERR
assertion RT to RT transfer 2
Notes:
1. Measured from last data word mid-bit parity crossing.
2. No response from transmitter.
* Supplied as a design limit but not guaranteed or tested.
MINIMUM
23.50
55.4
MAXIMUM
23.63
UNITS
µs
55.5
µs
RTI-34