DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

5962G8957701VYA View Datasheet(PDF) - Aeroflex UTMC

Part Name
Description
Manufacturer
5962G8957701VYA
UTMC
Aeroflex UTMC UTMC
5962G8957701VYA Datasheet PDF : 61 Pages
First Prev 41 42 43 44 45 46 47 48 49 50 Next Last
11.0 DC ELECTRICAL CHARACTERISTICS
(VDD = 5.0V ± 10%; -55°C < TC < + 125°C)
SYMBOL
VIL
Rad and
Non-Rad
VIH
Non-Rad
PARAMETER
Low-level input voltage
TTL inputs
High-level input voltage
TTL inputs
VIH
Rad-Hard
High-level input voltage 6
TTL inputs 7
CONDITION
MINIMUM MAXIMUM UNIT
0.8
V
2.0
V
2.2
V
IIN
Non-Rad
Input leakage current
TTL inputs
Inputs with pull-up resistors
Inputs with pull-up resistors
VIN = VDD or VSS
VIN = VDD
VIN = VSS
-1
-1
µA
-1
-1
µA
-550
-80
µA
IIN
Rad-Hard
VOL1
VOH1
Input leakage current
TTL7
Inputs with pull-up resistors
Inputs with pull-up resistors
Low-level output voltage
TTL outputs
High-level output voltage
TTL outputs
VIN = VDD or VSS
VIN = VDD
VIN = VSS
IOL = 3.2mA
IOH = -400µA
-10
10
µA
-10
10
µA
-900
-150
µA
0.4
V
2.4
V
IOZ
Three-state output leakage current
TTL outputs
VO = VDD or VSS
-10
IOS
Short-circuit output current 1, 2
VDD = 5.5V, VO = VDD
VDD = 5.5V, VO = 0V
-110
CIN
Input capacitance 3
ƒ = 1MHz @ 0V
COUT
Output capacitance 3
ƒ = 1MHz @ 0V
CIO
Bidirect I/O capacitance 3
ƒ = 1MHz @ 0V
IDD
Average operating current 1, 4
ƒ = 12MHz, CL = 50pF
QIDD
Quiescent current8
See Note 5, Tc = +125oC
Tc = 25oC, -55oC
10
µA
110
mA
mA
10
pF
15
pF
20
pF
50
mA
1
mA
35
µA
Notes:
1. Supplied as a design limit, but not guaranteed or tested.
2. Not more than one output may be shorted at a time for a maximum duration of one second.
3. Measured only for initial qualification, and after process or design changes which may affect input/output capacitance.
4. Includes current through input pull-up. Instantaneous surge currents on the order of 1 ampere can occur during output switching.
Voltage supply should be adequately sized and decoupled to handle a large current surge.
5. All inputs with internal pull-ups should be left floating. All other inputs should be tied high or low.
6. Functional tests are conducted in accordance with MIL-STD-883 with the following input test conditions
VIH = VIH(min) +20%, -0%; VIL = VIL(max) +0%, -50%, as specified herein, for TTL-compatible inputs.
Devices may be tested using input voltage within the above specified range, but are guaranteed to VIH(min) and VIL(max).
7. To 1.0E6 total dose; above this level, CMOS I/Os required.
8. Guaranteed to pre- and post-irradiation limits.
BCRTM-41
 