M41T56
CLOCK OPERATION
The eight byte clock register (see Table 3) is used
to both set the clock and to read the date and time
from the clock, in a binary coded decimal format.
Seconds, Minutes, and Hours are contained within
the first three registers. Bits D6 and D7 of Clock
Register 2 (Hours Register) contain the CENTU-
RY ENABLE Bit (CEB) and the CENTURY Bit
(CB). Setting CEB to a '1' will cause CB to toggle,
either from '0' to '1' or from '1' to '0' at the turn of
the century (depending upon its initial state). If
CEB is set to a '0,' CB will not toggle. Bits D0
through D2 of Register 3 contain the Day (day of
week). Registers 4, 5, and 6 contain the Date (day
of month), Month, and Years. The final register is
the Control Register (this is described in the Clock
Calibration section). Bit D7 of Register 0 contains
the STOP Bit (ST). Setting this bit to a '1' will cause
the oscillator to stop.
If the device is expected to spend a significant
amount of time on the shelf, the oscillator may be
stopped to reduce current drain. When reset to a
'0' the oscillator restarts within one second.
The seven Clock Registers may be read one byte
at a time, or in a sequential block. The Control
Register (Address location 7) may be accessed in-
dependently. Provision has been made to assure
that a clock update does not occur while any of the
seven clock addresses are being read. If a clock
address is being read, an update of the clock reg-
isters will be delayed by 250ms to allow the READ
to be completed before the update occurs. This
will prevent a transition of data during the READ.
Note: This 250ms delay affects only the clock reg-
ister update and does not alter the actual clock
time.
Table 3. Register Map
Data
Address
D7
D6
D5
D4
D3
D2
D1
D0
Function/Range
BCD Format
0
ST
10 Seconds
Seconds
Seconds
00-59
1
X
10 Minutes
Minutes
Minutes
00-59
2
CEB (1) CB
10 Hours
Hours
Century/Hours 0-1/00-23
3
X
X
X
X
X
Day
Day
01-07
4
X
X
10 Date
Date
Date
01-31
5
X
X
X
10 M.
Month
Month
01-12
6
10 Years
Years
Year
00-99
7
OUT FT
S
Calibration
Control
Keys:
S = SIGN Bit
FT = FREQUENCY TEST Bit
ST = STOP Bit
OUT = Output level
X = Don't care
CEB = Century Enable Bit
CB = Century Bit
Note: 1. When CEB is set to '1,' CB will toggle from '0' to '1' or from '1' to '0' every 100 years (dependent upon the initial value set).
2. When CEB is set to '0,' CB will not toggle.