DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

MC-4516DA726F View Datasheet(PDF) - NEC => Renesas Technology

Part Name
Description
Manufacturer
MC-4516DA726F Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MC-4516DA726
5 [MC-4516DA726LF]
Parameter
Symbol
Test condition
MIN. MAX. Unit Notes
Operating current
ICC1 Burst length = 1, tRC tRC(MIN.) ,
IO = 0 mA
/CAS latency = 2
-A80
-A10
1,650 mA 1
1,470
/CAS latency = 3 -A80
1,740
-A10
1,560
Precharge standby current in ICC2P CKE VIL(MAX.), tCK = 15 ns
268 mA
power down mode
ICC2PS CKE VIL(MAX.), tCK =
26
Precharge standby current in ICC2N CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
non power down mode
Input signals are changed one time during 30 ns.
ICC2NS CKE VIH (MIN.), tCK = ,
Input signals are stable.
Active standby current in
ICC3P CKE VIL(MAX.), tCK = 15 ns
610 mA
108
340 mA
power down mode
ICC3PS CKE VIL(MAX.), tCK =
72
Active standby current in
ICC3N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
700 mA
non power down mode
Input signals are changed one time during 30 ns.
Operating current
ICC3NS CKE VIH (MIN.), tCK = ,
Input signals are stable.
ICC4 tCK tCK(MIN.) , IO = 0 mA
/CAS latency = 2 -A80
270
1,920 mA 2
(Burst mode)
-A10
1,560
/CAS latency = 3 -A80
2,190
-A10
1,920
CBR (Auto) refresh current ICC5 tRC tRC(MIN.)
/CAS latency = 2 -A80
2,640 mA 3
-A10
2,640
/CAS latency = 3 -A80
2,730
-A10
2,730
Self refresh current
ICC6 CKE 0.2 V
268 mA
Input leakage current
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
– 10 + 10 µA
Output leakage current
IO(L) DOUT is disabled, VO = 0 to 3.6 V
– 1.5 + 1.5 µA
High level output voltage
VOH IO = – 4.0 mA
2.4
V
Low level output voltage
VOL IO = + 4.0 mA
0.4 V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
Data Sheet M13203EJ3V0DS00
7
 

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]