DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

HCPL-0452-000E View Datasheet(PDF) - Avago Technologies

Part Name
Description
Manufacturer
HCPL-0452-000E
AVAGO
Avago Technologies AVAGO
HCPL-0452-000E Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics (OPTION 060 ONLY)
Characteristic
Description
Symbol HCPL-4502/4503
Installation classification per DIN VDE 0110/39, Table 1
  for rated mains voltage ≤ 300 Vrms I-IV
  for rated mains voltage ≤ 600 Vrms
I-IV
Climatic Classification
55/100/21
HCPL-0452/0453
I-IV
I-I I I
55/100/21
Pollution Degree (DIN VDE 0110/39)
2
2
Maximum Working Insulation Voltage
VIORM
Input to Output Test Voltage, Method b*
 VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
VPR
  Partial Discharge < 5 pC
630
1181
560
1050
Input to Output Test Voltage, Method a*
 VIORM x 1.6 = VPR, Type and sample test,
 tm = 10 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 60 sec)
Safety Limiting Values
  (Maximum values allowed in the event of a failure,
  also see Figure 9, Thermal Derating curve.)
  Case Temperature
  Input Current
  Output Power
Insulation Resistance at TS, VIO = 500 V
VPR
VIOTM
1008
8000
TS
IS,INPUT
PS,OUTPUT
RS
175
230
600
≥109
896
6000
175
150
600
≥109
Units
V peak
V peak
V peak
V peak
°C
mA
mW
Ω
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics (HCNW4502/3 ONLY)
            Description
Symbol
Installation classification per DIN VDE 0110/39, Table 1
  for rated mains voltage ≤600 V rms
  for rated mains voltage ≤1000 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
VIORM
Input to Output Test Voltage, Method b*
 VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
VPR
  Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
 VIORM x 1.6 = VPR, Type and sample test,
 tm = 10 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 60 sec)
Safety Limiting Values
  (Maximum values allowed in the event of a failure,
  also see Figure 9, Thermal Derating curve.)
  Case Temperature
  Input Current
  Output Power
Insulation Resistance at TS, VIO = 500 V
VPR
VIOTM
TS
IS,INPUT
PS,OUTPUT
RS
Characteristic
Units
I-IV
I-III
55/85/21
2
1414
V peak
2652
V peak
2262
V peak
8000
V peak
150
°C
400
mA
700
mW
≥ 109
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
8
 