2 – Military ProASIC3/EL DC and Switching
Characteristics
General Specifications
Operating Conditions
Stresses beyond those listed in Table 2-1 may cause permanent damage to the device.
Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
absolute maximum ratings are stress ratings only; functional operation of the device at these or
any other conditions beyond those listed under the Recommended Operating Conditions specified
in Table 2-2 on page 2-2 is not implied.
Table 2-1 • Absolute Maximum Ratings
Symbol
Parameter
Limits
Units
VCC
DC core supply voltage
–0.3 to 1.65
V
VJTAG
JTAG DC voltage
–0.3 to 3.75
V
VPUMP
Programming voltage
–0.3 to 3.75
V
VCCPLL
Analog power supply (PLL)
–0.3 to 1.65
V
VCCI
DC I/O output buffer supply
–0.3 to 3.75
V
voltage for A3PE600L and
A3PE3000L. DC Output buffer
supply voltage for A3P1000.
VI
I/O input voltage
–0.3 V to 3.6 V (when I/O hot insertion mode is V
enabled)
–0.3 V to (VCCI + 1 V) or 3.6 V, whichever voltage
is lower (when I/O hot-insertion mode is
disabled)
VMV
DC input buffer supply voltage for
–0.3 to 3.75
V
A3P1000
TSTG 2
TJ 2
Storage temperature
Junction temperature
–65 to +150
°C
+150
°C
Notes:
1. The device should be operated within the limits specified by the datasheet. During transitions, the input
signal may undershoot or overshoot according to the limits shown in Table 2-4 on page 2-7.
2. For flash programming and retention maximum limits, refer to Table 2-3 on page 2-3, and for
recommended operating limits, refer to Table 2-2 on page 2-2.
v1.0