DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

ADF4360-1BCPZRL7 View Datasheet(PDF) - Analog Devices

Part Name
Description
Manufacturer
ADF4360-1BCPZRL7
ADI
Analog Devices ADI
ADF4360-1BCPZRL7 Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Data Sheet
ADF4360-1
CIRCUIT DESCRIPTION
REFERENCE INPUT SECTION
The reference input stage is shown in Figure 10. SW1 and SW2
are normally closed switches. SW3 is normally open. When
power-down is initiated, SW3 is closed, and SW1 and SW2 are
opened. This ensures that there is no loading of the REFIN pin
on power-down.
POΩER-DOΩN
CONTROL
NC 100k
REFIN NC
SΩ2
SΩ1
SΩ3
NO
TO R COUNTER
BUFFER
Figure 10. Reference Input Stage
PRESCALER (P/P + 1)
The dual-modulus prescaler (P/P + 1), along with the A and B
counters, enables the large division ratio, N, to be realized (N =
BP + A). The dual-modulus prescaler, operating at CML levels,
takes the clock from the VCO and divides it down to a manage-
able frequency for the CMOS A and B counters. The prescaler is
programmable. It can be set in software to 8/9, 16/17, or 32/33
and is based on a synchronous 4/5 core. There is a minimum
divide ratio possible for fully contiguous output frequencies;
this minimum is determined by P, the prescaler value, and is
given by (P2−P).
A AND B COUNTERS
The A and B CMOS counters combine with the dual-modulus
prescaler to allow a wide range division ratio in the PLL feed-
back counter. The counters are specified to work when the
prescaler output is 300 MHz or less. Thus, with a VCO
frequency of 2.5 GHz, a prescaler value of 16/17 is valid, but a
value of 8/9 is not valid.
Pulse Swallow Function
The A and B counters, in conjunction with the dual-modulus
prescaler, make it possible to generate output frequencies that
are spaced only by the reference frequency divided by R. The
VCO frequency equation is
fVCO = [(P × B)+ AfREFIN / R
where:
fVCO is the output frequency of the VCO.
P is the preset modulus of the dual-modulus prescaler (8/9,
16/17, and so on).
B is the preset divide ratio of the binary 13-bit counter (3 to 8191).
A is the preset divide ratio of the binary 5-bit swallow counter (0 to 31).
fREFIN is the external reference frequency oscillator.
FROM VCO
N = BP + A
PRESCALER
P/P+1
MODULUS
CONTROL
13-BIT B
COUNTER
LOAD
LOAD
5-BIT A
COUNTER
TO PFD
N DIVIDER
R COUNTER
Figure 11. A and B Counters
The 14-bit R counter allows the input reference frequency to
be divided down to produce the reference clock to the phase
frequency detector (PFD). Division ratios from 1 to 16,383 are
allowed.
PFD AND CHARGE PUMP
The PFD takes inputs from the R counter and N counter
(N = BP + A) and produces an output proportional to the phase
and frequency difference between them. Figure 12 is a simpli-
fied schematic. The PFD includes a programmable delay ele-
ment that controls the width of the antibacklash pulse. This
pulse ensures that there is no dead zone in the PFD transfer
function and minimizes phase noise and reference spurs. Two
bits in the R counter latch, ABP2 and ABP1, control the width
of the pulse (see Table 9).
HI
R DIVIDER
UP
D1
Q1
U1
CLR1
VP CHARGE
PUMP
PROGRAMMABLE
U3
DELAY
ABP1
ABP2
HI
N DIVIDER
CLR2
DOWN
D2
Q2
U2
CP
CPGND
R DIVIDER
N DIVIDER
CP OUTPUT
Figure 12. PFD Simplified Schematic and Timing (In Lock)
Rev. C | Page 9 of 24
 

Share Link: 