DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

ACC02A10SL-3S(025) View Datasheet(PDF) - Amphenol Aerospace

Part Name
Description
Manufacturer
ACC02A10SL-3S(025) Datasheet PDF : 44 Pages
First Prev 31 32 33 34 35 36 37 38 39 40 Next Last
AC Series
solder contacts
Machined copper alloy contacts in a full range of sizes, with closed entry socket design in the
size 12 and 16 contacts. A heavy silver-plated finish is deposited on all solder contacts for
maximum corrosion resistance, maximum current carrying capacity and low millivolt drop.
Part
Number
10-40569
10-597107-161
or 10-597424-001
10-40599
10-597107-171
or 10-597422-001
10-33646
10-597107-131
10-35531
10-35532
10-35529
10-35530
10-35527
10-35528
Pin/
Socket
Pin
Socket
Pin
Socket
Pin
Socket
Pin
Socket
Pin
Socket
Pin
Socket
SOLDER CONTACTS*
Mating End
Size
Wire Barrel
Size
16 Short†
16
16 Long
16
12
12
8
8
4
4
0
0
* Solder Wells Filled
** Contact ratings as stated are test ratings only. The connector may not withstand full rated current
through all contacts continuously. Please note that the electrical data given is not an establishment of
electrical safety factors. This is left entirely in the designer’s hands as he can best determine which peak
voltage, switching surges, transients, etc. can be expected in a particular circuit.
† The 10SL, 12S, 14S and 16S connectors require short contacts.
Allowable
Wire Size
16
18
20
22
16
18
20
22
12
14
8
10
4
6
0
1
2
Test Current**
Amps
13
10
7.5
5
13
10
7.5
5
23
17
46
33
80
60
150
125
100
Table I
CONTACT ARRANGEMENT
SERVICE RATING
MS
Service
Rating
Inst.
Recommended
Effective
OperatingVoltage* Creepage Mechanical
at Sea Level
Distance Spacing
D C AC (RMS)
Nom.
Nom.
250
200
1/16
A
700
500
1/8
1/16
D
1250
900
3/16
1/8
E
1750
1250
1/4
3/16
B
2450
1750
5/16
1/4
C
4200
3000
1
5/16
* The values listed in Table I represent operating values
which include a generous safety factor. It may be nec-
essary for some applications to exceed the operating
voltages listed here. If this is necessary, designers will
find Table II useful for determining the degree to which
the recommended values of Table I can be exceeded.
Table II
ALTITUDE VOLTAGE
DERATING** CHART
Nominal
Distance
MS
Service
Rating Airspace
Inst.
1/32
A
1/16
D
1/8
E
3/16
B
1/4
C
5/16
Creepage
1/16
1/8
3/16
1/4
5/16
1
Standard Sea
Level Conditions
Pressure Altitude
50,000 Feet
Minimum
Flashover
Voltage
AC (RMS)
Minimum
Test Flashover
Voltage Voltage
AC (RMS) AC (RMS)
Test
Voltage
AC (RMS)
1400
1000
550
400
2800
2000
800
600
3600
2800
900
675
4500
3500
1000
750
5700
4500
1100
825
8500
7000
1300
975
Pressure Altitude
70,000 Feet
Minimum
Flashover
Voltage
AC (RMS)
Test
Voltage
AC (RMS)
325
260
450
360
500
400
550
440
600
480
700
560
† Not corrected for changes in density due to variations in temperature
** No attempt has been made to recommend operating voltages. The designer must determine his own
operating voltage by the application of a safety factor to the above derating chart to compensate for
circuit transients, surges, etc.
34
 