DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

GRM155R70G105KA12D View Datasheet(PDF) - Murata Manufacturing

Part Name
Description
Manufacturer
GRM155R70G105KA12D
Murata
Murata Manufacturing Murata
GRM155R70G105KA12D Datasheet PDF : 30 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Specifications and Test Methods
No.
Item
1 Rated Voltage
Shown in Rated value.
Specification
2 Appearance
3 Dimension
4 Voltage Proof
No defects or abnormalities.
Shown in Rated value.
No defects or abnormalities.
5 Insulation Resistance(I.R.)
More than 50ΩF
6 Capacitance
Shown in Rated value.
7 Q or Dissipation Factor (D.F.) DF:0.125 max.
8 Capacitance
Temperature
Characteristics
No bias
Within +/-15%
(-55to +125)
GRM155R70G105KA12-01A
Test Method (Ref. Standard:JIS C 5101, IEC60384)
The rated voltage is defined as the maximum voltage which may be applied continuously to the capacitor.
When AC voltage is superimposed on DC voltage, VP-P or VO-P, whichever is larger, should be maintained
within the rated voltage range.
Visual inspection.
Using Measuring instrument of dimension.
Measurement Point :
Between the terminations
Test Voltage :
250% of the rated voltage
Applied Time :
1s to 5s
Charge/Discharge Current : 50mA max.
Measurement Temperature: Room Temperature
Measurement Point :
Between the terminations
Measurement Voltage : Rated Voltage
Charging Time :
1min
Charge/Discharge Current : 50mA max.
Measurement Temperature: Room Temperature
Measurement Frequency : 1.0+/-0.1kHz
Measurement Voltage : 1.0+/-0.2Vrms
Measurement Temperature : Room Temperature
Measurement Frequency : 1.0+/-0.1kHz
Measurement Voltage : 1.0+/-0.2Vrms
The capacitance change should be measured after 5 minutes at each specified temperature stage.
Capacitance value as a reference is the value in "*" marked step.
Measurement Voltage : Less than 1.0Vrms (Refer to the individual data sheet)
Step
1
2
3*
4
5
Tem perature(°C)
Reference Temp. +/-2
Min. Operating Temp. +/-3
Reference Temp. +/-2
Max. Operating Temp. ±3
Reference Temp. +/-2
Applying Voltage
No bias
Pre-treatment :
Perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 24+/-2hours at room temperature, then measure.
 

Share Link: 