DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

MAP110-4002CT View Datasheet(PDF) - Power-One Inc.

Part Name
Description
Manufacturer
MAP110-4002CT Datasheet PDF : 5 Pages
1 2 3 4 5
MAP110 SERIES
OUTPUT SPECIFICATIONS
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
CONDITIONS/DESCRIPTION
Full load, 230 VAC. Varies with distribution of loads among outputs.
Single output models.
Multiple output models, V1 + V2 (Note 1).
Full Load, 20 MHz Bandwidth.
Multiple output units with convection cooling.
Multiple output units with 200 LFM forced air cooling.
Output voltage overshoot/undershoot at turn-on.
Varies by output, regulation includes: line changes from 90-132
VAC or 175-264, changes in load starting at 20% load and changing
to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only on multiple output units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
MIN
NOM
MAX
UNITS
65
75
80
%
0
Amps
1
Amps
See Model Selection Chart.
5
80
Watts
5
110
Watts
0
V
See Model Selection Chart.
500
µS
1
Sec
20
mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
Overvoltage Protection
Overload Protection
Remote Sense
Input Power Fail
Warning
Overtemperature Protection
CONDITIONS/DESCRIPTION
Provided on single output models and the
main output of multiple output models.
MAP110-1005
MAP110-1012
MAP110-1024
MAP110-4200
MAP110-4300
All other models.
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
Voltage drop compensated for at the load.
Option, TTL compatible logic signal. Time before regulation dropout due
to loss of input power at 110 VAC. Active low.
Option, system shutdown due to excessive internal temperature.
MIN
NOM
MAX
UNITS
6.10
7.20
17.3
20.2
32.2
37.8
V
13.8
16.2
3.7
4.35
5.75
6.75
150
200
%
250
mV
3
5
mS
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic
Interference,
Conducted
Input Transient Protection
Insulation Resistance
Leakage Current
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Input to Output.
FCC CFR title 47 part 15 sub-part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated (Note 2).
EN61000-4-5 level 3.
Input to output.
Per EN60950, 264 VAC.
MIN
2600
2
10
NOTES: 1) Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is necessary.
2) The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300.
NOM
MAX
Approved.
B
B
A
750
UNITS
VDC
Class
kV
M
µA
3
 