DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

MAP110-4002 View Datasheet(PDF) - Power-One Inc.

Part Name
Description
Manufacturer
MAP110-4002 Datasheet PDF : 5 Pages
1 2 3 4 5
MAP110 SERIES
MULTIPLE OUTPUT MODEL SELECTION CHART (CONT.) – 80W CONVECTION COOLED, 110W FORCED AIR COOLED (200 LFM)
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
CONVECTION COOLED
CURRENT (NOTE 1)
FORCED AIR
CURRENT
LINE
REGULATION
LOAD
REGULATION
+5V
4.75V to 5.25V
12A/20A PK
12A/20A PK
0.2%
0.5%
MAP110-4010
+12V
-5V
Fixed
Fixed
5A/9A PK
1A/1.5A PK
5A/9A PK
1A/1.5A PK
0.1%
0.2%
2%
1.5%
-12V
Fixed
3A/4A PK
3A/4A PK
0.3%
8%
+5V
4.75V to 5.25V
12A/20A PK
12A/20A PK
0.2%
0.5%
MAP110-4011
+12V
Fixed
5A/9A PK
5A/9A PK
0.1%
1%
-12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
+24V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
+5V
4.75V to 5.25V
12A/20A PK
12A/20A PK
0.2%
0.5%
MAP110-4015
+12V
Fixed
5A/9A PK
5A/9A PK
0.1%
1%
-15V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
+15V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
1%
+12V
11.55V to 12.45V
5A/9A PK
5A/9A PK
0.2%
0.5%
MAP110-4200
+24V
Fixed
4A/4.5A PK
4A/4.5A PK
0.2%
1%
-12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.2%
1%
+5V
Fixed
2A/2.5A PK
2A/2.5A PK
0.2%
1.5%
New
MAP110-4300
(Note 3)
+3.3V
+5V
-12V
+12V
3.2V to 3.4V
Fixed
Fixed
Fixed
12A/20A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
0.3%
0.2%
0.1%
0.1%
0.7%
1%
1%
1%
New
MAP110-4305
(Note 3)
+3.3V
+5V
-5V
+12V
3.2V to 3.4V
Fixed
Fixed
Fixed
12A/15A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
0.3%
0.2%
0.1%
0.1%
0.7%
1%
1%
1%
NOTES: 1) Peak loads up to 110 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 Watts.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Sum of the output currents of V1 + V2 may not exceed 15A continuous, 22A peak.
RIPPLE & NOISE
%p-p (NOTE 2)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
0.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
INITIAL SETTING
ACCURACY
5.09V to 5.11V
11.97V to 12.03V
-4.75V to -5.25V
-11.5V to -12.5V
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
23.2V to 24.8V
5.09V to 5.11V
11.97V to 12.03V
-14.4V to -15.6V
14.4V to 15.6V
11.96V to 12.03V
23.94V to 24.06V
-11.4V to -12.6V
4.75V to 5.25V
3.29V to 3.31V
4.98V to 5.02V
-11.4V to -12.6V
11.4V to 12.6V
3.29V to 3.31V
4.98V to 5.02V
-4.75V to -5.25V
11.4V to 12.6V
MAXIMUM OUTPUT RATING:
MODEL/OUTPUT
OPTION
CONVECTION
CONTINUOUS/PEAK
FORCED AIR
200 LFM
MULTIPLE OUTPUT
BOARD ONLY
80W/110W
110W
SINGLE OUTPUT
BOARD ONLY
90W/120W
120W
MULTIPLE OUTPUT
‘L’-BRACKET
80W/110W
110W
SINGLE OUTPUT
‘L’-BRACKET
90W/120W
120W
MULTIPLE OUTPUT
‘C’-COVER
60W/110W
110W
SINGLE OUTPUT
C’-COVER
65W/120W
120W
INPUT SPECIFICATIONS
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC input voltage (110 VAC)
50% load:
Full rated load:
85 VAC (110W load).
110VAC (110W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264 VAC (one cycle). 25°C.
Operating Frequency
Switching frequency of main transformer, (fixed frequency).
MIN
NOM
MAX
UNITS
85
264
VAC
47
63
Hz
85
VAC
40
mS
20
3.5
ARMS
2.8
41
APK
20
25
kHz
2
 

Share Link: 