How to select a heat sink
How To Select a Heat Sink
The basic equation for heat transfer or power dissipation may be stated as follows:
ΔT
PD = ΣRθ
Where:
PD = the power dissipated by the semiconductor device in watts.
ΔT = the temperature difference of driving potential which causes the flow of heat.
ΣRθ = the sum of the thermal resistances of the heat flow path across which ΔT exists.
The above relationship may be stated in the following forms:
PD =
TJ–TA
RθJC + RθCS + RθSA
PD =
TC–TA
RθCS + RθSA
PD =
TS–TA
RθSA
Where:
TJ = the junction temperature in °C (maximum is usually stated by the manufacturer of the semiconductor device).
TC = case temperature of the semiconductor device in °C.
TS = temperature of the heat sink mounting surface in thermal contact with the semiconductor device in °C.
TA = ambient air temperature in °C.
RθJC = thermal resistance from junction to case of the semiconductor device in °C per watt
(usually stated by manufacturer of semiconductor device).
RθCS = thermal resistance through the interface between the semiconductor device
and the surface on which it is mounted in °C per watt.
RθSA = thermal resistance from mounting surface to ambient or thermal resistance of heat sink in °C per watt.
The above equations are generally used to determine the required thermal resistance of the heat sink (RθSA),
since the heat dissipation, maximum junction and/or case temperature, and ambient temperature are known or set.
Figure 1 indicates the location of the various heat
flow paths, temperatures and thermal resistances.
The common practice is to represent the system with
a network of resistances in series as shown in Figure 2.
FIGURE 1
Mounting surface
(cooler/dissipator)
Interface
Junction
(heat source)
PD
Semiconductor case
Atmosphere
or ambient
TA
PD
FIGURE 2
TJ
TC
TS
TA
RθCS
RθSA
Heat flow path mounting
surface to ambient, equation (3)
RθJC
TS
TC
Heat flow path case
to ambient equation (2)
Heat flow path junction
to ambient, equation (1)
TJ
TA
RθJC
RθCS
RθSA
AMERICA USA Tel: +1 (603) 224-9988 email: info@aavid.com
ASIA Singapore Tel: +65 6362 8388 email: sales@aavid.com.sg
EUROPE Italy Tel: +39 051 764011 email: sales.it@aavid.com
Taiwan Tel: +886(2) 2698-9888 email: sales@aavid.com.tw
9
www.aavidthermalloy.com
United Kingdom Tel: +44 1793 401400 email: sales.uk@aavid.com
 

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]