1,000
500
OPERATION HERE
LIMITED BY RDS (ON)
10µS
100µS
100
1mS
50
10mS
10
5
TC =+25°C
TJ =+150°C
SINGLE PULSE
100mS
DC
1
1
5 10
50 100
VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS)
FIGURE 10, MAXIMUM SAFE OPERATING AREA
20
ID = 100A
VDS=20V
16
VDS=50V
12
VDS=80V
8
4
0
0 200 400 600 800 1000 1200 1400
Qg, TOTAL GATE CHARGE (nC)
FIGURE 12, GATE CHARGES vs GATE-TO-SOURCE VOLTAGE
50,000
10,000
5,000
APT10M07JVR
Ciss
Coss
Crss
1,000
.01
.1
1
10
50
VDS, DRAIN-TO-SOURCE VOLTAGE (VOLTS)
FIGURE 11, TYPICAL CAPACITANCE vs DRAIN-TO-SOURCE VOLTAGE
500
100
TJ =+150°C
TJ =+25°C
50
10
5
1
0
0.4
0.8
1.2
1.6
2.0
VSD, SOURCE-TO-DRAIN VOLTAGE (VOLTS)
FIGURE 13, TYPICAL SOURCE-DRAIN DIODE FORWARD VOLTAGE
r = 4.0 (.157)
(2 places)
SOT-227 (ISOTOP®) Package Outline
31.5 (1.240)
31.7 (1.248)
7.8 (.307)
8.2 (.322)
W=4.1 (.161)
W=4.3 (.169)
H=4.8 (.187)
H=4.9 (.193)
(4 places)
11.8 (.463)
12.2 (.480)
8.9 (.350)
9.6 (.378)
Hex Nut M4
(4 places)
4.0 (.157)
4.2 (.165)
(2 places)
25.2 (0.992)
0.75 (.030) 12.6 (.496) 25.4 (1.000)
0.85 (.033) 12.8 (.504)
3.3 (.129)
3.6 (.143)
1.95 (.077)
2.14 (.084)
14.9 (.587)
15.1 (.594)
* Source
Drain
30.1 (1.185)
30.3 (1.193)
38.0 (1.496)
38.2 (1.504)
* Source terminals are shorted
internally. Current handling
capability is equal for either
Source terminal.
* Source
Gate
Dimensions in Millimeters and (Inches)
ISOTOP® is a Registered Trademark of SGS Thomson.
"UL Recognized" File No. E145592
APT's devices are covered by one or more of the following U.S.patents: 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522 5,262,336
5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058