40
Mechanical pressure switches
Liquids and gases
DCM25
DCM/DNM
Pressure switches and pressure monitors for overpressure
This universal pressure switch can be used in
general mechanical engineering and the printing
machine industry, as well as in pneumatics and
hydraulics.
SIL 2 according IEC 61508-2
Technical data
Pressure connection
External thread G 1/2 (pressure gauge
connection) according to DIN 16 288 and inter-
nal thread G 1/4 according to ISO 228 Part 1.
Switching device
Robust housing (200) made of seawater-
resistant diecast aluminium GD Al Si 12.
Protection class
IP 54, in vertical position.
Pressure sensor materials
DNM025…DCM63 Metal bellows: 1.4571
Sensor housing: 1.4104
DCM025 – DCM 1 Metal bellows: Cu Sensor
housing: Cu + Ms
DCM4016/
Diaphragm: Perbunan
DCM4025
Sensor housing: 1.4301
DCM1000
Diaphragm: Perbunan
Sensor housing: Brass
Mounting position
Vertically upright and horizontal. DCM4016
and 4025 vertically upright.
Ambient temp. at switching device
–25…+70 °C, except: DCM4016,
4025, 1000: –15…+60 °C
Max. medium temperature
The maximum medium temperature at the
pressure sensor must not exceed the
permitted ambient temperature at the
switching device. Temperatures may reach
85°C for short periods). Higher medium
temperatures are possible provided the above
limit values for the switching device are
ensured by suitable measures (e.g. siphon).
Mounting
Directly on the pressure line (pressure
gaugeconnection) or on a flat surface with two
4 mm Ø screws.
Switching pressure
Adjustable from outside with screwdriver.
Switching differential
Not adjustable with DCM and types. Adjustable
from outside with DCMV types. For values see
Product Summary.
Contact arrangement
Single-pole changeover switch.
Switching
capacity
Normal
250 VAC 250 VDC 24 VDC
(ohm) (ind) (ohm) (ohm)
8 A 5 A 0.3 A 8 A
Type
Setting range
Switching
Max.
Materials in- Dimen-
differential permissible contact with sioned
(mean values) pressure medium
drawing
Switching differential not adjustable
DCM4016
1…16 mbar
2
DCM4025
4…25 mbar
2
DCM1000 10…100 mbar
12
DCM025 0.04…0.25 bar
0.03
DCM06
0.1…0,6 bar
0.04
DCM1
0.2…1,6 bar
0.04
DNM025 0.04…0.25 bar
0.03
DCM506
15…60 mbar
10
DCM3
0.2…2.5 bar
0.1
DCM6
0.5…6 bar
0.15
DCM625
0.5…6 bar
0.25
DCM10
1…10 bar
0,3
DCM16
3…16 bar
0.5
DCM25
4…25 bar
1.0
DCM40
8…40 bar
1.3
DCM63
16…63 bar
2.0
mbar 1 bar
mbar 1 bar
mbar 10 bar
bar 6 bar
bar 6 bar
bar 6 bar
bar 6 bar
mbar 12 bar
bar 16 bar
bar 16 bar
bar 25 bar
bar 25 bar
bar 25 bar
bar 60 bar
bar 60 bar
bar 130 bar
Perbunan
+ 1.4301
Perbunan + MS
Cu + Ms
Cu + Ms
Cu + Ms
Sensor
housing
1.4104
+
Pressure
bellow
1.4571
page 25 + 26
1 + 11
1 + 10
1 + 14
1 + 15
1 + 12
1 + 18
1 + 17
1 + 16
Switching differential adjustable
DCMV025 0.04…0.25 bar 0.03…0.4 bar
DCMV06 0.1…0.6 bar 0.04…0.5 bar
DCMV1
0.2…1.6 bar 0.07…0.55 bar
DCMV3
0.2…2.5 bar 0.15…1.5 bar
DCMV6
0.5…6 bar 0.25…2.0 bar
DCMV625 0.5…6 bar 0.25…2.0 bar
DCMV10
1…10 bar 0.5…2.8 bar
DCMV16
3…16 bar 0.7…3.5 bar
DCMV25
4…25 bar 1.3…6.0 bar
DCMV40
8…40 bar 2.6…6.6 bar
DCMV63
16…63 bar 3.0…10 bar
6 bar
6 bar
6 bar
16 bar
16 bar
25 bar
25 bar
25 bar
60 bar
60 bar
130 bar
Cu + Ms
Sensor
housing
1.4104
+
Pressure
bellow
1.4571
1 + 14
1 + 18
1 + 17
1 + 16
For smaller pressure ranges see also VCM, DGM, HCD and DPS sheets.
For additional functions refer page 30 – 32.
Calibration
The DCM series is calibrated for falling pressure. This means that the adjustable switching pressure on
the scale corresponds to the switching point at falling pressure. The reset point is higher by the amount
of the switching differential. (See also page 27, 1. Calibration at lower switching point).
-DCM/DNM
see page 65
s
Protection Class:
IP 54
 