DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

UEI-5/15-Q12P-C View Datasheet(PDF) - Murata Power Solutions

Part Name
Description
Manufacturer
UEI-5/15-Q12P-C
Murata-ps
Murata Power Solutions Murata-ps
UEI-5/15-Q12P-C Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
UEI Series
50-60W Isolated Wide-Range DC/DC Converters
ISOLATION CHARACTERISTICS
Model Family
UEI-3.3/15-Q12
UEI-3.3/18-Q48
UEI-5/10-Q12
UEI-5/12-Q48
UEI-12/4.2-Q12
UEI-12/5-Q48
UEI-15/3.3-Q12
UEI-15/4-Q48
Input to
Output.
Min
VDC
2000
2250
2000
2250
2000
2250
2000
2250
Isolation
Resistance
Min
Isolation
Capacitance
Isolation Safety
Rating
pF
10
10
10
10
10
1000
Basic
insulation
10
10
10
DYNAMIC CHARACTERISTICS
Model Family
Dynamic Load
Start-up Time
Response
(50-75-50%
load step)
VIN to VOUT Remote On/Off Switching
regulated
to VOUT
Frequency
(Max.) regulated (Max.)
μsec
mSec
mSec
KHz
UEI-3.3/15-Q12
100 to 2% VOUT
275
UEI-3.3/18-Q48
180 to 2% VOUT
280
UEI-5/10-Q12
100 to 2% VOUT
UEI-5/12-Q48
275
50
50
UEI-12/4.2-Q12
200 to 1% VOUT
UEI-12/5-Q48
400 to 1% VOUT
250
UEI-15/3.3-Q12
150 to 1% VOUT
265
UEI-15/4-Q48
TBD
TBD
MISCELLANEOUS CHARACTERISTICS
Model Family
Output Current
Limit Inception Output
Short
98% of VOUT,
after warmup
A
Circuit
Protection
Method
UEI-3.3/15-Q12
20
UEI-3.3/18-Q48
23
UEI-5/10-Q12
14
Current
UEI-5/12-Q48
15.5
limiting,
hiccup
UEI-12/4.2-Q12
6
auto
UEI-12/5-Q48
6.1
restart
UEI-15/3.3-Q12
5.3
UEI-15/4-Q48
5.8
Output
Short
Circuit
Current
A
0.5
0.06
0.5
TBD
Output
Short Circuit
Duration
(output shorted
Pre-biased
setup
Calculated
MTBF
to ground)
Hours
Continuous
Monotonic
(external 2,000,000
VOUT < VSET)
Operating Temperature
Range
Storage
temperature
range
Thermal
protection/
shutdown
Relative
Humidity,
non-
condensing
ºC
ºC
ºC
–40 to +85ºC;
with Derating
(see Notes)
–55 to 125ºC 115
To +85ºC/
85%
Specification Notes:
(1) All models are tested and specified with external 1||10 μF output capacitors and a 22 μF external
input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate
our test equipment and may not be required to achieve specified performance in your applications. All
models are stable and regulate within spec under no-load conditions.
All specifications are typical unless noted. General conditions for Specifications are +25 deg.C,
Vin=nominal, Vout=nominal, full load. Adequate airflow must be supplied for extended testing under
power.
(2) Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering
is Cin=33 μF, 100V, Cbus=220 μF, 100V, Lbus=12 μH.
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage.
At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current
outputs if the total RMS current over time does not exceed the Derating curve. All Derating curves
are presented at sea level altitude. Be aware of reduced power dissipation with increasing density
altitude.
(4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3,
ground fixed conditions, Tpcboard=+25 deg.C, full load, natural air convection.
(5) The On/Off Control is normally selected by a switch or an open collector or open drain transistor.
But it may also be driven with external logic or by applying appropriate external voltages which are
referenced to Input Common and do not exceed the On/Off voltage specifications.
(6) Output current limiting begins when the output voltage degrades approximately 2% from the
selected setting.
(7) The outputs are not intended to sink appreciable reverse current.
(8) Output noise may be further reduced by adding an external filter. Low voltage logic circuits may
have a small voltage margin between logic ZERO and logic ONE, requiring noise suppression. Use only
as much output filtering as needed to achieve your noise requirements. Excessive output capacitance
can retard transient response or possibly cause instability. Low ESR ceramic capacitors may degrade
dynamic performance. Be sure to thoroughly test your system under full load with all components
installed.
(9) All models are fully operational and meet published specifications, including “cold start” at –40°C.
At full power, the package temperature of all on-board components must not exceed +128°C.
(10) Regulation specifications describe the deviation as the line input voltage or output load current is
varied from a nominal midpoint value to either extreme.
(11) The output overvoltage protection is automatic recovery. The overvoltage may occur either from
internal failure or from an external forcing voltage as in a shared power system.
(12) Output current limit and short circuit protection is non-latching. When the overcurrent fault is
removed, the converter will immediately recover. After an output overcurrent or short circuit, “hiccup”
operation repeatedly attempts to restart the converter with a brief, full-current output. If the overcur-
rent condition still exists, the restart current will be removed and then tried again. This short current
pulse prevents overheating and damaging the converter. Once the fault is removed, the converter
immediately resumes normal operation.
(13) Do not exceed maximum power specifications when adjusting the output trim.
(14) At zero output current, the output may contain low frequency components which exceed the
ripple specification. The output may be operated indefinitely with no load.
(15) If reverse polarity is accidentally applied to the input, to ensure reverse input protection with full
output load, always connect an external input fuse in series with the +Vin input. Use approximately
twice the full input current rating with nominal input voltage.
CAUTION: This product is not internally fused. To comply with safety agency certifications and to
avoid injury to personnel or equipment, the user must connect an external fast-blow fuse to the input
terminals. See fuse information.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_UEI Series 50-60W.B24 Page 5 of 12
 

Share Link: 