TPS60110
REGULATED 5ĆV 300ĆmA LOWĆNOISE
CHARGE PUMP DC/DC CONVERTER
SLVS215C − JUNE 1999 − REVISED AUGUST 2008
detailed description
operating principle
The TPS60110 charge pump provides a regulated 5-V output from a 2.7-V to 5.4-V input. It delivers a maximum
load current of 300 mA. Designed specifically for space critical battery powered applications, the complete
charge pump circuit requires only four external capacitors. The circuit can be optimized for highest efficiency
at light loads or lowest output noise. The TPS60110 consists of an oscillator, a 1.22-V bandgap reference, an
internal resistive feedback circuit, an error amplifier, high current MOSFET switches, a shutdown/start-up
circuit, and a control circuit (Figure 23)
SKIP
COM
CLK
OSCILLATOR
0°
180°
CONTROL
CIRCUIT
CHARGE PUMP 1
T11
T12
T13
T14
IN
C1+
C1F
C1−
OUT
PGND
FB
SYNC
ENABLE
SHUTDOWN/
START-UP
CONTROL
+
VREF
+
+
+− 0.8 × VIN
CHARGE PUMP 2
T21
T22
T23
T24
IN
C2+
C2F
C2−
OUT
PGND
GND
Figure 23. Functional Block Diagram TPS60110
The oscillator runs at a 50% duty cycle. The device consists of two single-ended charge pumps which operate
with 180° phase shift. Each single ended charge pump transfers charge into its transfer capacitor (CxF) in one
half of the period. During the other half of the period (transfer phase), CxF is placed in series with the input to
transfer its charge to CO. While one single-ended charge pump is in the charge phase, the other one is in the
transfer phase. This operation specifies an almost constant output current which ensures a low output ripple.
If the clock were to run continuously, this process would eventually generate an output voltage equal to two times
the input voltage (hence the name doubler). In order to provide a regulated fixed output voltage of 5 V, the
TPS60110 uses either pulse-skip mode or constant-frequency mode. Pulse-skip mode and constant-frequency
mode are externally selected via the SKIP input pin.