TLP3051(S), TLP3052(S)
Absolute Maximum Ratings (Ta=25°C)
CHARACTERISTIC
SYMBOL RATING UNIT
Forward Current
Forward Current Derating (Ta53°C)
Peak Forward Current (100μs pulse, 100pps)
Power Dissipation
Power Dissipation Derating (Ta25°C)
Reverse Voltage
Junction Temperature
Off-State Output Terminal Voltage
On-State RMS Current
Ta=25°C
Ta=70°C
IF
IF /°C
IFP
PD
PD /°C
VR
Tj
VDRM
IT(RMS)
50
0.7
1
100
-1.0
5
125
600
100
50
mA
mA /°C
A
mW
mW/°C
V
°C
V
mA
On-State Current Derating (Ta25°C)
Peak On-State Current (100μs pulse, 120pps)
IT/°C
ITP
-1.1 mA /°C
2
A
Peak Nonrepetitive Surge Current (Pw=10ms,DC=10%)
Power Dissipation
Power Dissipation Derating (Ta25°C)
Junction Temperature
Storage Temperature Range
Operating Temperature Range
Lead Soldering Temperature (10s)
Total Package Power Dissipation
Total Package Power Dissipation Derating (Ta25°C)
Isolation Voltage (AC,1min. , R.H.60%)
(Note 2)
ITSM
PD
PD /°C
Tj
Tstg
Topr
Tsol
PT
PT/°C
BVS
1.2
A
300
mW
-4.0 mW/°C
115
°C
55~150 °C
40~100 °C
260
°C
330
mW
-4.4 mW /°C
5000
Vrms
Note: Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the
significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even
if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum
ratings.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
(“Handling Precautions”/“Derating Concept and Methods”) and individual reliability data (i.e. reliability test
report and estimated failure rate, etc).
(Note 2) Device considered a two terminal device :Pins1, 2 and 3 shorted together and pin 4 and pin 6 shorted
together.
Recommended Operating Conditions
CHARACTERISTIC
SYMBOL MIN. TYP. MAX. UNIT
Supply Voltage
Forward Current
Peak On-State Current
Operating Temperature
VAC
240
Vac
IF*
15
20
25
mA
ITP
——
1
A
Topr
25 —
85
°C
Note: Recommended operating conditions are given as a design guideline to obtain expected performance of the
device. Additionally, each item is an independent guideline respectively. In developing designs using this
product, please confirm specified characteristics shown in this document.
*In The case of TLP3052
2
2007-10-01
 