STU2071
Maintenance and service channel.
The ternary symbols M1 and M2 represent non-
scrambled data that can be transmitted at a rate
of 1 kBaud. Those symbols are used for various
purposes:
- Maintenance Channel (control test loops
(LT NT) and frame errors (LT NT)
- Service channel (transparent user data and
transmit messages from NT to LT)
Encoding.
The encoding of a binary bit stream is made such
that 4 binary bits correspond to 3 symbols of ter-
nary symbol stream. The encoding follows the
rules of modified monitoring state 43 (MMS43).
COMMAND / INDICATE CHANNEL (A bits)
Command/Indicate codes are define depending on the mode selected (LT or NT).
NT mode COMMANDS (DIN)
ACT
1000
Activate.
Layer 1 is activated at the UK0 interface starting with a ’wake-up’ signal INFO
U1W, followed by INFO U1A during synchronization and closed by INFO U1
when synch is gained.
AW
0000
Awake.
Set the module interface from the power-down to the power-up state. No signal
is emitted at UK0 interface. Even DIN pin pulled LOW can have the same effect.
DC
1111
Deactivation confirmation.
The module interface is deactivated. The transmitter is disabled but the receiver
is still enabled to recognize an awake signal. THe UIC is set in power down
state.
RES
1101
Reset.
Reset the UIC to the initial state.
SY
1100
Synchronize.
Drive the UIC in connect through from module interface to line interface.
Remark: Executing the command RES (1101) is functionally equivalent to pulling the RESETN pin (6)
LOW, with one exception:
a) RES command set pin DISS to HIGH (+5V)
b) pulling RESETN LOW set pin DISS to LOW (0V).
NT mode INDICATION (DOUT)
ACT
DC
DEAC
CT
CTL2
L2
RSYN
1000
1111
0000
1100
1110
1010
0100
Activate.
The synchronous state of the receiver is reached.
Deactivation confirmation.
The transmitter is disabled but the receiver remains enabled to detect awake
signals at UK0 UIC is set in power down state.
Deactivate.
A request to deactivate INFO U0 has been detected.
Connection Through.
The UIC is fully activated.
Connection through with loop 2.
A loop 2 command has been detected at UK0.
Loop 2.
Synchronization has been reached during a Loop 2 activation procedure.
Resynchronization.
The receiver has lost framing and is attempting to resynchronize.