CN8223
ATM Transmitter/Receiver with UTOPIA Interface
2.0 Functional Description
2.4 Status and Alarms
2.4 Status and Alarms
The CN8223 automatically receives and generates alarms.
2.4.1 Status and Counter Interrupts
The status interrupt pin STAT_INT can be programmed to provide an interrupt on
any occurrence in the LINE_STATUS register [0x38]. Each of these signals
generates a receive status interrupt if the corresponding interrupt is enabled in the
EN_LINE_INT register [0x2D]. To determine if an interrupt is caused by a PHY
status event, the LINE_STATUS register is read. This clears the interrupts in that
register.
Two types of interrupts are provided: error and alarm. Error signals cause an
interrupt on each occurrence of an error condition. Error signals are bits 913 in
the LINE_STATUS register. Alarm signals provide an interrupt on change of
state. All other indications in LINE_STATUS are alarm indications.
Interrupt status bits for the line/PHY counter overflows are located in the
OVFL_STATUS register [0x3A]. The enables for these interrupts are in
EN_OVFL_INT [0x2F]. All counters are 16 bits. If a counter is set to interrupt, it
rolls over to zero when it exceeds its maximum value. If a counter is not set to
interrupt, it saturates at its maximum value of 65,535 and ignores further events.
To determine if an interrupt has been caused by a counter, the microprocessor
reads the OVFL_STATUS register.
If the interrupt for a particular counter is not set, the counter saturates at a
value of 65,535 and stays at that value until read. If Enable One-Second Latching
of Line Counters [bit 13 in CONFIG_1 [0x00] is set, then at each one-second
interval defined by the input ONESECI, the current counter value is latched for
the following one-second interval, and the counter is cleared. If the counter is
again read in that one-second interval, the current value of the counter is read and
then cleared.
The LCV counter [0x40] is always latched (and the counter cleared) by the
ONESECI input regardless of the setting of Enable One-Second Latching of Line
Counters. When this counter is read, the latched value is presented and then
cleared. Subsequent reads prior to the next ONESECI latching event produce a
value of zero.