Philips Semiconductors
±1 °C accurate, SMBus-compatible, 8-pin, remote/local
digital temperature sensor with over temperature alarms
Product data sheet
SA56004X
PIN CONFIGURATION
SO8 and TSSOP8
TOP VIEW
VDD 1
8 SCLK
D+ 2
7 SDATA
SA56004X
D– 3
6 ALERT
T_CRIT 4
5 GND
SL02014
Figure 2. Pin configuration.
PIN DESCRIPTION
PIN SYMBOL
DESCRIPTION
1 VDD
Positive supply voltage. DC voltage from 3.0 V
to 5.5 V.
2 D+
Diode current source (anode).
3 D–
Diode sink current (cathode).
4 T_CRIT T_CRIT alarm is open drain, active-LOW output
which requires an external pull-up resistor. It
functions as a system interrupt or power
shutdown.
5 GND
Power supply ground.
6 ALERT
ALERT alarm is an open drain, active-LOW
output which requires an external pull-up resistor.
It functions as an interrupt indicating that the
temperature of the on-chip or remote diode is
above or below programmed over temperature
or under temperature thresholds.
7 SDATA SMBus/I2C-bus bi-directional data line. This is
an open drain output which requires an external
pull-up resistor.
8 SCLK
SMBus/I2C-bus clock input which requires an
external pull-up resistor.
MAXIMUM RATINGS
All voltages are referenced to GND.
SYMBOL
PARAMETER
MIN.
MAX.
UNIT
VDD
Supply voltage
Voltage at SDATA, SCLK, ALERT, T_CRIT
–0.3
+6
V
–0.3
+6
V
VD+
Voltage at Positive diode input
VD–
Voltage at Negative diode input
Sink current at SDATA, SCLK, ALERT, T_CRIT
–0.3
VDD + 0.3
V
–0.3
+0.8
V
–1
50
mA
ID+
D+ input current
–1
PD
Power dissipation
SO8 package (derate 5.9 mW/°C above Tamb = 70 °C)
–
TSSOP8 package (derate 8.3 mW/°C above Tamb = 70 °C)
–
Vesd
ESD
Human Body Model (Note 1)
–
Machine Model (Note 1)
–
1
mA
471
mW
664
mW
2000
V
200
V
Tj(max)
Maximum junction temperature
–
+150
°C
Tstg
Storage temperature range
–65
+165
°C
NOTES:
1. The D+ and D– pins are 1000 V HBM and 100 V MM due to the higher sensitivity of the analog pins that introduces a limitation to the circuit
protection structure.
2004 Oct 06