Long Term Safe Operating Area Curves*
600
500
400
300
200
100
0
-100
-200
-300
-400
-500
-600
10-6
1µs
28Vdc Input
Ratings Exceeded
OVP
50V
Reverse Polarity
Protection
10-5
10-4
10-3
10-2
10-1
100
10µs
100µs
1ms
10ms
100ms
1s
TIME (SECONDS)
* 1% duty cycle max., for short duration transient capability refer to specifications
270Vdc Input
800
600
400
200
0
200
400
600
10-6
1µs
Ratings Exceeded
OVP
500V
400V
Reverse Polarity
Protection
10-5
10-4
10-3
10-2
10-1
100
10µs
100µs
1ms
10ms
100ms
1s
TIME (SECONDS)
Disable Circuit
+
V
20 mA Max.
Disable
DIS+
Disable Current
• 4mA DC minimum for 1-up ComPAC
• 8mA DC minimum for 2-up ComPAC
DIS–
• 12mA DC minimum for 3-up ComPAC
The MI-ComPAC incorporates an optically isolated master disable input which will shut down the
MI-ComPAC when a current is driven through the disable terminals.
Thermal Considerations
Thermal Impedance — Case-to-Air (°C/W)
Free Air (Horiz.)
Standard Units
1-up
3.6
2-up
1.7
3-up
1.4
With Optional Heat Sink (1)
1-up
2.1
2-up
1.3
3-up
1.0
50 LFM
100 LFM
250 LFM
500 LFM
750 LFM
1000 LFM
Forced Convection Through Heat Sink Fins
2.7
1.4
1.3
2.3
1.3
1.1
1.6
1.0
0.8
1.2
0.7
0.6
0.9
0.5
0.5
0.8
0.4
0.4
1.5
1.1
0.9
1.2
0.9
0.7
0.7
0.5
0.4
0.4
0.3
0.3
0.3
0.2
0.2
0.2
0.2
0.2
• Thermal impedance, chassis-to-air, is provided for 1-up, 2-up and 3-up MI-ComPAC
package configurations as a function of air flow.
• Case temperature = (total power dissipated x thermal impedance) + ambient temperature.
• Watts dissipated per output = (output power ÷ efficiency) – output power.
(1) To order optional heat sink add –H1 to part number