MB39A110
■ SETTING THE OUTPUT VOLTAGE
• CH1 to CH4
VO
R1
−INEX
R2
CSX
Error
− Amp
+
+
1.23 V
1.23
VO (V) =
R2
(R1 + R2)
X: Each channel No.
■ SETTING THE TRIANGULAR OSCILLATION FREQUENCY
The triangular oscillation frequency is determined by the timing resistor (RT) connected to the RT terminal
(pin 12), and the timing capacitor (CT) connected to the CT terminal (pin 13).
Triangular oscillation frequency : fOSC
fOSC
(kHz)
=:
693600
CT (pF) × RT (kΩ)
15