DC and AC parameters
7
DC and AC parameters
M29W800DT, M29W800DB
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow, are derived from tests performed under the measurement conditions summarized in
Table 9: Operating and AC measurement conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Table 9.
Operating and AC measurement conditions
M29W800D
Parameter
45 ns
70 ns
90 ns
Unit
VCC supply voltage
Ambient operating temperature (range 6)
Ambient operating temperature (range 1)
Load capacitance (CL)
Input rise and fall times
Input pulse voltages
Input and output timing ref. voltages
Min Max Min Max Min Max
3.0 3.6 2.7 3.6 2.7 3.6 V
–40 85 –40 85 –40 85
°C
0
70
0
70
0
70
30
30
100
pF
10
10
10 ns
0 to VCC
VCC/2
0 to VCC
VCC/2
0 to VCC
V
VCC/2
V
Figure 9. AC measurement I/O waveform
VCC
0V
VCC/2
AI04498
28/52