LC72131KMA View Datasheet(PDF) - SANYO -> Panasonic

Part Name
Description
Manufacturer
LC72131KMA
SANYO
SANYO -> Panasonic SANYO
LC72131KMA Datasheet PDF : 22 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
LC72131K, LC72131KMA
Control Data Functions
No.
Control block/data
Functions
(1) Programmable
divider data
P0 to P15
Data that sets the divisor of the programmable divider.
A binary value in which P15 is the MSB. The LSB changes depending on
DVS and SNS. (*: don’t care)
DVS
SNS
LSB
Divisor setting (N)
1
*
P0
0
1
P0
0
0
P4
272 to 65535
272 to 65535
4 to 4095
Note: P0 to P3 are ignored when P4 is the LSB.
Actual divisor
Twice the value of the setting
The value of the setting
The value of the setting
Related data
DVS, SNS
(2) Reference divider
data
R0 to R3
Selects the signal input pin (AMIN or FMIN) for the programmable divider, switches
the input frequency range. (*: don’t care)
DVS
SNS
Input pin
Input frequency range
1
*
0
1
0
0
FMIN
AMIN
AMIN
10 to 160MHz
2 to 40MHz
0.5 to 10MHz
Note: See the “Programmable Divider Structure” item for more information.
Reference frequency (fref) selection data.
R3
R2
R1
R0
Reference frequency
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
100kHz
50
25
25
12.5
6.25
3.125
3.125
1
0
0
0
10
1
0
0
1
9
1
0
1
0
5
1
0
1
1
1
1
1
0
0
3
1
1
0
1
15
1
1
1
0
* PLL INHIBIT + X'tal OSC STOP
1
1
1
1
* PLL INHIBIT
Note *: PLL INHIBIT
The programmable divider block and the IF counter block are stopped, the FMIN, AMIN,
and IFIN pins are set to the pull-down state (ground), and the charge pump goes to the
high impedance state.
XS
(3) IF counter control
data
CTE
GT0, GT1
Crystal resonator selection
XS=0: 4.5MHz
XS=1: 7.2MHz
The 7.2MHz frequency is selected after the power-on reset.
IF counter measurement start data
CTE=1: Counter start
=0: Counter reset
Determines the IF counter measurement period.
GT1
GT0
Measurement time (ms)
0
0
4
0
1
8
1
0
32
1
1
64
Note: See the “IF Counter Structure” item for more information.
IFS
Wait time (ms)
3 to 4
3 to 4
7 to 8
7 to 8
Continued on next page.
No.A0788-9/22
 

Share Link: 