IRL3705Z/S/L
100000
10000
1000
VGS = 0V, f = 1 MHZ
Ciss = C gs + Cgd, C ds SHORTED
Crss = C gd
Coss = Cds + Cgd
Ciss
Coss
Crss
100
1
10
100
VDS, Drain-to-Source Voltage (V)
Fig 5. Typical Capacitance vs.
Drain-to-Source Voltage
6.0
ID= 52A
5.0
4.0
VDS= 44V
VDS= 28V
VDS= 11V
3.0
2.0
1.0
0.0
0
10
20
30
40
QG Total Gate Charge (nC)
Fig 6. Typical Gate Charge vs.
Gate-to-Source Voltage
1000.00
100.00
TJ = 175°C
1000
100
OPERATION IN THIS AREA
LIMITED BY R DS(on)
10.00
TJ = 25°C
1.00
0.0
VGS = 0V
0.5
1.0
1.5
2.0
VSD, Source-to-Drain Voltage (V)
Fig 7. Typical Source-Drain Diode
Forward Voltage
4
100µsec
10
Tc = 25°C
Tj = 175°C
Single Pulse
1
1
10
1msec
10msec
100
VDS, Drain-to-Source Voltage (V)
1000
Fig 8. Maximum Safe Operating Area
www.irf.com