Embedded Power for
Business-Critical Continuity
EMC Charateristics
Immunity:
ESD air enclosure:
Input transients:
EN61000-4-2 8 kV, 6 kV (Air contact)
IBC25AET4812 60 V. 100 ms
IBC20AES4812 60 V. 100 ms
IBC17AEW4812 100 V. 100 ms
General Specifications
Efficiency:
See table
Basic insulation:
Input/output 2250 Vdc
Switching frequency: Fixed 600 kHz typ.
Approvals and
EN60950-1 VDE
standards (see note 5): UL/cUL60950-1
Rev.11.25.08_136
Eighth-Brick IBC Series
 of 3
Environmental Specifications
Thermal
Operating ambient temperature -40 °C to +85 °C
performance: Non-operating -55 °C to +125 °C
Protection
Short-circuit:
Overvoltage: (See note 9)
Thermal:
Hiccup
Non-latching
125 °C hot spot
Material flammability:
Weight:
MTBF
Representative model:
UL94V-0
33 g (1.16 oz)
Telcordia Tech SR-332 5,500,000 hours
48 Vin, 40 °C, 50% load
ground benign
All specifications are typical at nominal input, full load at 25° C unless otherwise stated.
Ordering Information
Output
Power
(Max.)
300 W
240 W
200 W
Input
Voltage
42 - 53 Vdc
42 - 53 Vdc
36 - 75 Vdc
Output
Voltage
12 V
12 V
12 V
Output
Current
(Min.)
0A
0A
0A
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
Output Current Efficiency
(Max.)
(Typ.)
25 A
95.5%
20 A
94.5%
17 A
94.0%
Set Point
Accuracy %
---
±0.25%
±0.25%
Regulation2 (typical)
Line %
Load %
+10, -12.5%
±0.3%
±1.0%
±1.5%
-2/-1.5%
-3/+2%
Model Number
IBC25AET4812J
IBC20AES4812J
IBC17AEW4812J
Part Number System with Options
Product Family
IBC
Rated Output
Current
17A
Form Factor
E
Input Voltage Type
W
Input
Voltage
48
Output
Voltage
Remote ON/
OFF Logic
12 - R
IBC Intermediate 17 A =
Bus Converter 17 Amps etc.
2nd Generation
E = Eighth-
Brick
Q = Quarter-
brick
S = Sixteenth-
brick
T = Narrow Input
Fixed Ratio
S = Narrow Input
Semi-reguated
N = Narrow Telecom
Fixed Ratio
W = Wide Telecom
Semi-reguated
48 = 48 V 12 = 12 V
Blank =
Positive
R = Negative
(See Note 6)
Module Height
Pin Length
Options
RoHS Compliance (7, 8)
A
N
J
A = Open-frame
0.40 in (10.2
mm)
E = Open-rame,
0.45 in (11.4
mm)
Blank = 0.188 ”
(4.78 mm)
N = 0.145 ”
(3.68 mm)
K = 0.110 ”
(2.79 mm)
J = Pb-free
(RoHS 6/6
compliant)
Y = RoHS 5/6
compliant
Notes
1 Recommended input fusing is a 20 A HRC 250 V rated fuse.
2 Measured with external filter. See Application Note 182 for details.
3 Start-up into resistive load.
4 Peak to peak measured without external Pi filter. Significant reduction
possible with external filter. See Application Note 182 for details.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6 Active-low remote ON/OFF option is also available. Please add the suffix ‘-R’
to the part number, e.g. IBC17AEW4812-RAJ.
7 TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
8 NOTICE: Some models do not support all options. Please contact your local
Sales representative or use the on-line model number search tool at http://
www.powerconversion.com to find a suitable alternative.
 

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]