Regulatory Information
The HCPL-0302/3020 has been approved by the following organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01.
(Option 060 only)
UL
Approval under UL 1577, component recognition pro-
gram up to VISO = 3750 VRMS. File E55361.
CSA
Approval under CSA Component Acceptance Notice #5,
File CA 88324.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics (HCPL-3020 and HCPL-0302 Option 060)
Description
Symbol HCPL-3020 HCPL-0302 Unit
Installation Classification per DIN VDE 0110/1.89, Table 1
  for Rated Mains Voltage ­ 150 Vrms
I – IV
I – IV
  for Rated Mains Voltage ­ 300 Vrms
I – III
I – III
  for Rated Mains Voltage ­ 600 Vrms
I – II
Climatic Classification
55/100/21 55/100/21
Pollution Degree (DIN VDE 0110/1.89)
2
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b [1]
VIORM
630
566
Vpeak
  VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
  Partial Discharge < 5 pC
Input to Output Test Voltage, Method a [1]
VPR
1181
1050
Vpeak
  VIORM x 1.5 = VPR, Type and Sample Test, tm = 60 sec,
  Partial Discharge < 5 pC
VPR
945
840
Vpeak
Highest Allowable Overvoltage
  (Transient Overvoltage tini = 10 sec)
VIOTM
6000
4000
Vpeak
Safety-Limiting Values – Maximum Values Allowed in the Event of a
Failure.
  Case Temperature
  Input Current [2]
  Output Power [2]
Insulation Resistance at TS, VIO = 500 V
TS
IS, INPUT
PS, OUTPUT
RS
175
230
600
>109
150
°C
150
mA
600
mW
>109
1. Refer to the optocoupler section of the Isolation and Control Compo-
nents Designer’s Catalog, under Product Safety Regulations section,
(IEC/EN/DIN EN 60747-5-2), for a detailed description of Method a
and Method b partial discharge test profiles.
2. Refer to the following figure for dependence of PS and IS on ambient
temperature.
800
700
PS (mW)
IS (mA)
600
500
400
300
200
100
0
0 25 50 75 100 125 150 175 200
TS – CASE TEMPERATURE – C

 