First Prev 11 12 13 14 15 16 17 18 19 20
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
FH12 Seriesq0.5mm and 1mm Pitch Connectors For FPC/FFC
qBottom Contact Type (common for 0.5mm/1mm Pitch)
Operation
Precautions
3) Rotate down the actuator until firmly closed.
It is critical that the inserted FPC/FFC is not moved
and remains fully inserted. Should the FPC/FFC be
moved, open the actuator and repeat the process,
starting with Step 1.
6) Partial insertion of the FPC/FFC, offset insertion, and
diagonal insertion will result in an unfavorable engage-
ment of the lock lever in which the lock lever is raised.
To correct this, first remove the FPC/FFC and then
reinsert it. Forcing the lock will damage the connector.
Stiffener
7) When locking, handle the FPC/FFC so that a load
is not applied to the FPC/FFC as would occur by
pulling the FPC/FFC, or lifting it, etc.
When a load is applied in the opposite direction to
the rotational movement of the lock, an excessive
load will be applied and this will cause connector
damage.
2. FPC/FFC Removal
1) Lift up the actuator.
2) Carefully remove the FPC/FFC.
8) At the time of lock operation, application of force
such as that indicated by the arrows in the dia-
grams below will cause the lock lever to disengage.
When the lock lever has become disengaged,
please exchange the entire connector.