COMMAND DEFINITIONS
EN29LV160C
The operations of the EN29LV160C are selected by one or more commands written into the command
register to perform Read/Reset Memory, Read ID, Read Sector Protection, Program, Sector Erase,
Chip Erase, Erase Suspend and Erase Resume. Commands are made up of data sequences written at
specific addresses via the command register. The sequences for the specified operation are defined in
the Command Definitions table (Table 5). Incorrect addresses, incorrect data values or improper
sequences will reset the device to Read Mode.
Table 9. EN29LV160C Command Definitions
Bus Cycles
Command
Sequence
Read
1
Reset
1
Manufacturer
ID
Word
Byte
4
Device ID
Top Boot
Word 4
Byte
1st
Write Cycle
Add Data
RA RD
xxx F0
555
AA
AAA
555 AA
AAA
2nd
Write Cycle
Add Data
2AA
55
555
2AA 55
555
3rd
Write Cycle
Add Data
555
90
AAA
555 90
AAA
4th
Write Cycle
Add Data
000 7F
100 1C
000 7F
200 1C
x01 22C4
x02 C4
5th
Write Cycle
Add Data
6th
Write Cycle
Add Data
Device ID
Bottom Boot
Word 4
Byte
555 AA
AAA
2AA 55
555
555 90
AAA
x01 2249
x02 49
Word
Sector Protect
Verify
4
Byte
555
AA
AAA
2AA
55
555
555
90
AAA
(SA)
X02
(SA)
X04
XX00
XX01
00
01
08
Program
Word
Byte
4
555
AAA
AA
2AA
555
55
555
AAA
A0
PA PD
Chip Erase
Word
Byte
6
555
AAA
AA
2AA
555
55
555
AAA
80
555
AAA
AA
2AA
555
55
555
AAA
10
Sector Erase
Word
Byte
6
555
AAA
AA
2AA
555
55
555
AAA
80
555
AAA
AA
2AA
555
55
SA
30
Erase Suspend
1 xxx B0
Erase Resume
1 xxx 30
CFI Query
Word 1
Byte
55 98
AA
Enter Secured
Silicon Sector
Word
Byte
3
555
AAA
AA
2AA
555
55
555
AAA
88
Exit Secured
Silicon Sector
Word
Byte
4
555
AAA
AA
2AA
555
55
555
AAA
90
xxx
xxx
00
00
Address and Data values indicated in hex
RA = Read Address: address of the memory location to be read. This is a read cycle.
RD = Read Data: data read from location RA during Read operation. This is a read cycle.
PA = Program Address: address of the memory location to be programmed. X = Don’t-Care
PD = Program Data: data to be programmed at location PA
SA = Sector Address: address of the Sector to be erased or verified. Address bits A19-A12 uniquely select any
Sector.
This Data Sheet may be revised by subsequent versions
14
or modifications due to changes in technical specifications.
© 2004 Eon Silicon Solution, Inc.,
Rev. C, Issue Date: 2011/10/26
www.eonssi.com
 