DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

E5052B View Datasheet(PDF) - HP => Agilent Technologies

Part Name
Description
Manufacturer
E5052B Datasheet PDF : 21 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
AM Noise Measurement
Table 5-1. AM noise measurement performance
Description
RF frequency range
Effective offset frequency range
AM noise sensitivity
Measurement uncertainty1
Spurious level
Measurement trigger
Specification
60 MHz to 7 GHz
10 Hz to 40 MHz
(@ > carrier 400 MHz)
10 Hz to 10% of carrier frequency
(@ < carrier 400 MHz)
See Table 5-2.
± 4 dB (100 Hz to 1 kHz offset) typical
± 2 dB (1 kHz to 1 MHz offset) typical
± 3 dB (1 MHz to 40 MHz offset) typical
< –65 dBc/Hz (at > 1 kHz offset) typical
continuous/single/hold source: internal/external/manual/bus
Table 5-2. AM noise sensitivity [dBc/Hz]
correlation = 1, RF input: 0 dBm, > 400 MHz
AM noise sensitivity
Offset frequency (Hz) from the carrier
1
10
100
1k
10 k
100 k
1M
E5052B start frequency = 1 Hz, measurement time = 13 s
specification
–127
–138
–147
–150
typical
–103
–117
–131
–142
–151
–154
E5052B-011 (Option 011) start frequency = 10 Hz, measurement time = 3.3 s
specification
–124
–135
–144
–147
typical
–100
–114
–128
–139
–148
–151
1. AM noise measurement uncertainty: specified at 10 MHz and 1 GHz of carrier
frequency with 0 dBm level. AM level > –60 dBc
10 M
–154
–158
–151
–155
40 M
–155
–159
–152
–156
10
 