9.9 POWER OFF CD Function
The ‘POWER OFF CD’ function describes a state which, after the system has been shut down and a +5V analog power is
supplied at VAUX(pin-34), the ALC250 will turn on the CD-IN op and output amplifier. It is possible to design a system which
will save op-amp circuitry and bypass CD output directly to the speaker.
The figure below indicates the system application circuitry to support the ‘POWER OFF CD’ function. The operation mode is
defined by +3.3VCC and +5Vaux.
+3.3VCC
No (0)
No (0)
Yes (1)
Yes (1)
+5Vaux
No (0)
Yes (1)
No (0)
Yes (1)
Operation Mode
Shut Down
Power Off CD
Normal (+5Vaudio must be on)
Normal (+5Vaudio must be on)
+
0.1u
10u
+5VA
+5Vstandby
D1
+3.3VDD
1N5817M/CYL
D2
+
10u
0.1u
1N5817M/CYL
U3
2
3
XTL-IN
XTL-OUT
LINEOUT-L
35
36
LINEOUT-R
MONO-OUT/VREFOUT3
37
11
6
10
5
RESET#
BITCLK
SYNC
8
SDOUT
SDIN
VREF
VREFOUT
27
28
29
AFILT1
AFILT2
30
31
12
13
14
PC-BEEP
PHONE
ALC250
NC 32
DCVOL
VREFOUT2
33
34
1
2
0
1u
0
15
16
17
18
20
21
AUX-L
AUX-R
JD2
JD1
CD-L
CD-R
VAUX
GPIO0
GPIO1
NC
XTLSEL
SPDIFI/EAPD
43
44
45
46
47
48
3
4
1u
22
23
MIC1
MIC2
SPDIFO
HPOUT-L
39
40
24 LINE-L
NC 41
0
LINE-R
HPOUT-R
1u
POWER OFF CD Circuitry
Two Channel AC’97 2.3 Audio Codec
38
Tel: +49(0)234-9351135 · Fax: +49(0)234-9351137 E-MAIL: info@cornelius-consult.de
Rev1.01