TEMPERATURE LINEARIZATION SCHEME
The ADP1051 linearization scheme is based on a combination of
a thermistor (R25 = 100 kΩ, 1%), an external resistor (16.5 kΩ,
1%), and the 46 µA current source, preselected for best
performance when linearizing measured temperatures in the
industrial range.
The NTC thermistor that is required must have a resistance of
R25 = 100 kΩ, 1%, such as the NCP15WF104F03RC (beta = 4250,
1%). It is recommended that 1% tolerance be used for both the
resistor and beta values. The linearization equations show the
relationship between the RTD voltage, VRTD (in volts), and
temperature reading, T (in degrees Celsius).
If T < 104°C,
1.6
VRTD = (130 – T) × 256
If T ≥ 104°C,
1.6
VRTD = (156 – T) × 512
where T represents the temperature reading in Register 0x8D.
Figure 37 shows the temperature linearization curves.
0.8
LINEARIZATION VOLT-TEMP CURVE
ACTUAL VOLT-TEMP CURVE
0.7
0.6
0.5
0.4
Using the internal linearization scheme, the READ_TEMPERA-
TURE command (Register 0x8D) returns the current temperature
in degrees Celsius. For overtemperature protection, the user can
directly set the OT_FAULT_LIMIT command (Register 0x4F) in
degrees Celsius. See the OT_FAULT and OT_WARNING section
for more information.
PMBUS PROTECTION COMMANDS
VOUT Overvoltage Protection (OVP)
The VOUT overvoltage protection feature in the ADP1051
follows PMBus specifications. The limits are programmed in
the VOUT_OV_FAULT_LIMIT command (Register 0x40) to
correspond to the voltage between 75% and 150% of the nominal
output voltage. The responses are programmed using the VOUT_
OV_FAULT_RESPONSE command (Register 0x41). The
VOUT_OV_FAULT flag (Register 0x78[5], Register 0x79[5],
and Register 0x7A[7]) is set when the voltage reading exceeds the
overvoltage limit.
In a direct parallel system, multiple power supply units are
connected directly in parallel without any OR’ing device. An
overvoltage condition in one power supply can raise the common
bus voltage, causing the activation of overvoltage protection in
the other power supplies connected to the common bus. As a
result of this overvoltage protection action, the common bus
may fail. The ADP1051 provides a highly flexible, conditional
overvoltage protection function for redundant control in a direct
parallel system. It consists of an overvoltage detection block, a
modulation flag triggering block, and an overvoltage response
block (see Figure 38).
0.3
0.2
0.1
0
10 20 30 40 50 60 70 80 90 100 110 120 130
TEMPERATURE (°C)
Figure 37. Temperature Linearization Scheme Curves
VO
OVP
VS–
VOUT_OV_FAULT
DEBOUNCE
REG 0xFE26
OVP SELECTION
REG 0xFE6C[0]
VOUT_OV_FAULT
REG 0x7A[7]
VOUT_OV_FAULT_RESPONSE
REG 0x41
DAC
VOUT_OV_FAULT_LIMIT
REG 0x40
0
0 AND 0
MODULATION
VALUE
MODULATION
THRESHOLD
REG 0xFE6B
LARGE_MODULATION
REG 0xFE6C[2]
0
0
0 AND
EXTENDED
VOUT_OV_FAULT_RESPONSE
REG 0xFE01
Figure 38. VOUT Overvoltage Protection Circuit Implementation