DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

ADC219 View Datasheet(PDF) -

Part Name
Description
Manufacturer
ADC219
 
ADC219 Datasheet PDF : 0 Pages
ADC200 SERIES
1W, High Isolation SIP, Single & Dual Output DC/DC Converters
Absolute Maximum Ratings
Parameter
Min. Max. Units
5VDC Input Models -0.7 9 VDC
Input Surge Voltage 12VDC Input Models -0.7 18 VDC
(1000mS)
24VDC Input Models -0.7 30 VDC
Lead Temperature
(1.5mm from case for 10sec.)
--- 260 °C
Internal Power Dissipation
--- 450 mW
Exceeding the unit absolute maximum ratings could cause damage.
These are not continuous operating ratings.
General Characteristics
Parameter
Isolation
Voltage
Isolation
Resistance
Conditions
60 Seconds
500VDC
Isolation
Capacitance
100kHz, 1V
Switching
Frequency
MTBF
MIL-HDBK-217F
@25°C
Ground Benign
Min.
3000
10
---
70
2
Typ.
---
---
60
100
---
Max.
---
Units
VDC
---
G
100
pF
120
kHz
---
MHrs
Environmental Characteristics
Parameter
Conditions
Min. Max.
Operating
Temperature
Ambient
-40 85
Operating
Temperature
Case
-40 90
Storage
Temperature
-40 125
Humidity
--- 95
Cooling
Free-Air Convection
Units
°C
°C
°C
%
Derating Curve (3.3, 5 & ±5V Outputs)
100
100LFM
80
Natural
60
convection
200LFM
400LFM
Output Characteristics
Parameter
Conditions
Line Regulation
For Vin Change of
1%
Load Regulation Io = 20% to 100%
Min. Typ. Max.
---
±1.2 ±1.5
See Selection Guide
Ripple & Noise
Short Circuit
20MHz BW
---
65
100
0.5 Second Max.
Maximum Capacitive Load
Models by Output Voltage
(Each Output on Duals)
Singles
220
Duals
100
Notes:
Units
%
%
mV P-P
Units
uF
40
20
0
¡ã
-40
50
60
70
80
90
100
110
Ambient Temperature ]
Derating Curve (Other Outputs)
100
100LFM
400LFM
200LFM
80
1. Specifications typical at Ta=+25°C, resistive load, nominal input
voltage, rated output current unless otherwise noted.
2. These power converters require a minimum output load to maintain
specified regulation.
3. Operation under no-load conditions will not damage these modules;
however, they may not meet all specifications listed.
4. All DC/DC converters should be externally fused at the front end for
protection.
5. Other input and output voltage may be available, please contact
factory.
6. All specifications subject to change without notice.
7. For detailed data sheet, please visit our website.
60
Natural
40
convection
20
0
-40
¡ã
50
60
70
80
Ambient Temperature
90
]
100 110
2463 208th Street, Ste. 205
Torrance, CA 90501
Tel: (310) 533-1455
Fax: (310) 533-1853
http://www.mpsind.com
E-mail: sales@mpsind.com
 

Share Link: 