First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Functional Description (Continued)
put 0000 0000 digital code for this minimum input voltage by
biasing any VIN (−) input at this VIN(MIN) value. This utilizes
the differential mode operation of the A/D.
The zero error of the A/D converter relates to the location of
the first riser of the transfer function and can be measured by
grounding the VIN (−) input and applying a small magnitude
positive voltage to the VIN (+) input. Zero error is the differ-
ence between the actual DC input voltage which is neces-
sary to just cause an output digital code transition from 0000
0000 to 0000 0001 and the ideal 12 LSB value (12 LSB =
9.8mV for VREF = 5.000VDC).
5.2 Full Scale
The full-scale adjustment can be made by applying a differ-
ential input voltage which is 112 LSB down from the desired
analog full-scale voltage range and then adjusting the mag-
nitude of the VREFIN input (or VCC for the ADC08032) for a
digital output code which is just changing from 1111 1110 to
1111 1111.
5.3 Adjusting for an Arbitrary Analog Input
Voltage Range
If the analog zero voltage of the A/D is shifted away from
ground (for example, to accommodate an analog input signal
which does not go to ground), this new zero reference
should be properly adjusted first. A VIN (+) voltage which
equals this desired zero reference plus 12 LSB (where the
LSB is calculated for the desired analog span, using 1 LSB =
analog span/256) is applied to selected “+” input and the
zero reference voltage at the corresponding “−” input should
then be adjusted to just obtain the 00HEX to 01HEX code tran-
sition.
The full-scale adjustment should be made [with the proper
VIN (−) voltage applied] by forcing a voltage to the VIN (+) in-
put which is given by:
where:
VMAX = the high end of the analog input range
and
VMIN = the low end (the offset zero) of the analog range.
(Both are ground referenced.)
The VREFIN (or VCC) voltage is then adjusted to provide a
code change from FEHEX to FFHEX. This completes the ad-
justment procedure.