Plug-in relays
Mini ISO relays
Power relay F4
Ordering information (Production in Europe, Asia and South America)
Part numbers
(see table below for coil data)
Relay part number Tyco order number
12 V pcb relays
V23134-A0052-G243
2-1393302-3
V23134-A0052-X812*)
4-1393305-5
V23134-A0052-X813*)
4-1393305-7
V23134-B0052-G242
7-1393302-7
V23134-B0052-X802*)
2-1393305-2
V23134-C0052-G242
4-1393303-0
V23134-M0052-G242
5-1393304-7
24 V pcb relays
V23134-A0053-G243
5-1393302-2
V23134-A0064-X820*)
5-1393305-9
V23134-B0053-G242
1-1393303-0
V23134-C0053-G242
4-1393303-5
V23134-M0053-G242
6-1393304-8
Contact
arrangement
1 Form C
1 Form C
1 Form C
1 Form A
1 Form A
1 Form A (2 pins 87)
1 Form U
1 Form C
1 Form C
1 Form A
1 Form A (2 pins 87)
1 Form U
*) Marking according to VF4 shematic.
Contact
material
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
AgNi0.15
Enclosure
Dust cover
Sealed
Sealed
Dust cover
Sealed
Dust cover
Dust cover
Dust cover
Sealed
Dust cover
Dust cover
Dust cover
Catalog 1308028
Issued 01-05
Special
features
Resistor 680
Coil versions
Coil data
for Power relay F4
V23134-**052-****
V23134-**053-****
V23134-**056-****
V23134-**064-****
Rated coil
voltage
(V)
12
24
24
24
Coil
resistance
+/- 10%
()
91
332
275
345
1) Allowable overdrive is stated with no load applied and minimum coil resistance.
Must
operate
voltage
(V)
7.2
14.4
16.0
14.4
Standard delivery packs (orders in multiples of delivery pack)
Power relay F4
Quick connect verson:
Quick connect with bracket:
PCB version:
315 pieces
200 pieces
200 pieces
Must
release
voltage
(V)
1.6
3.2
4.0
2.4
Allowable overdrive 1)
voltage (V)
at 23 °C
at 85 °C
23
18
44
34
38
30
40.5
31.5
37
Please observe the disclaimer.
Direct download click here
HOME '3-1393303-4' Search

Features
– Limiting continuous currents 60/40 A at the NO / NC contacts
– Dimensional characteristics and the functional allocations of the plug-in terminals to ISO 7588
– Standardized dimensions
– 24 V versions with contact gap > 0.8 mm
– Plug-in or PCB terminals

Typical applications
– Ignition lock
– Lamp load (headlights)
– Cooling fan
– ABS
– Exhaust emission control
– Cross carline up to 60 A
– Fuel pump
– Engine cooling fan
– A/C blower
– A/C compressor clutch
– Also available for 42 V applications

 