PRELIMINARY
AC CHARACTERISTICS
Addresses
Program Command Sequence (last two cycles)
tWC
tAS
555h
PA
tAH
Read Status Data (last two cycles)
PA
PA
CE#
OE#
WE#
Data
tGHWL
tCH
tWP
tCS
tWPH
tDS
tDH
A0h
RY/BY#
VCC
tVCS
tWHWH1
PD
tBUSY
Status
DOUT
tRB
Notes:
1. PA = program address, PD = program data, DOUT is the true data at the program address.
2. Illustration shows device in word mode.
21358F-21
Figure 17. Program Operation Timings
Am29LV160B