M27V160
4
DC and AC parameters
DC and AC parameters
TA = 0 to 70°C or –40 to 85°C; VCC = 3.3V ± 10%; VPP = VCC
Table 5. Read Mode DC Characteristics (1)
Symbol
Parameter
Test Condition
Min. Max. Unit
ILI Input Leakage Current
0V ≤ VIN ≤ VCC
ILO Output Leakage Current
0V ≤ VOUT ≤ VCC
ICC Supply Current
E = VIL, G = VIL, IOUT = 0mA,
f = 8MHz, VCC ≤ 3.6V
E = VIL, G = VIL, IOUT = 0mA,
f = 5MHz, VCC ≤ 3.6V
ICC1 Supply Current (Standby) TTL
E = VIH
ICC2
Supply Current (Standby)
CMOS
E > VCC – 0.2V, VCC ≤ 3.6V
±1
µA
±10 µA
30
mA
20
mA
1
mA
60
µA
IPP Program Current
VPP = VCC
10
µA
VIL Input Low Voltage
VIH (2) Input High Voltage
–0.3 0.2VCC V
0.7VCC VCC + 1 V
VOL Output Low Voltage
IOL = 2.1mA
0.4
V
VOH Output High Voltage TTL
IOH = –400µA
2.4
V
1. VCC must be applied simultaneously with or before VPP and removed simultaneously or after VPP.
2. Maximum DC voltage on Output is VCC +0.5V.
TA = 25 °C; VCC = 6.25V ± 0.25V; VPP = 12.5V ± 0.25V
Table 6. Programming Mode DC Characteristics (1)
Symbol
Parameter
Test Condition
Min
Max
Unit
ILI Input Leakage Current
ICC Supply Current
IPP Program Current
VIL Input Low Voltage
VIH Input High Voltage
0 ≤ VIN ≤ VCC
E = VIL
±1
µA
50
mA
50
mA
–0.3
0.8
V
2.4
VCC +
0.5
V
VOL Output Low Voltage
VOH Output High Voltage TTL
VID A9 Voltage
IOL = 2.1mA
IOH = –2.5mA
0.4
V
3.6
V
11.5
12.5
V
1. VCC must be applied simultaneously with or before VPP and removed simultaneously or after VPP.