DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

MAX78615-LMU View Datasheet(PDF) - Maxim Integrated

Part Name
Description
Manufacturer
MAX78615-LMU
MaximIC
Maxim Integrated MaximIC
MAX78615-LMU Datasheet PDF : 62 Pages
First Prev 31 32 33 34 35 36 37 38 39 40 Next Last
MAX78615+LMU Data Sheet
Multipurpose (MP) Pins
The MAX78615+LMU provides five MASK registers for signaling the status of any STATUS bit to one of five
Multipurpose (MP) DIO pins. These MASK registers have the same bit mapping as the STATUS register. The user
must first enable the respective MP pin as an output before the DIO can be driven to its active state.
Pin Name
MP0
MP4
MP6/ADDR1
MP7
Register
MASK0
MASK4
MASK6
MASK7
Description
A combination of a bit set in both the STATUS register and
a MASK register causes the assigned MP pin to be
activated (default active-low).
Relay Control
If one of the RELAY bits in a MASK register is set, only the respective relay status bit in the STATUS register will
change the state of the assigned MP pin. Two options are provided for controlling the state of the RELAY status bit:
1. Manual control of relay status using the STATUS_SET and STATUS_RESET registers.
2. Autonomous control determined by the state of other bits in the STATUS and MASK register. For example, if a
MASK register has the RELAY1 and VA_SURGE bits set, a surge alarm on voltage source VA would assert the
RELAY1 status bit.
The MAX78615+LMU includes a programmable delay for driving the MP pins from the MASK register when the
relay bit is set. The relay control logic allows setting a delay time (increments of 250µs) for energizing (setting) and
de-energizing (clearing) the relay pin relative to the zero crossing of the referenced voltage source. The time
specified in the registers is expressed in number of high-rate samples. There is a pipeline delay of 1 sample
introduced by the timers.
Registers
RYA_TON
RYB_TON
RYA_TOFF
RYB_TOFF
Description
Relay turn-on delay following low-to-high transition of referenced voltage.
Relay turn-off delay following high-to-low transition of referenced voltage.
TOFF_DELAY
Line
Voltage
Relay
Command
De-Energized
TON_DELAY
Energized
Figure 22. Relay Control
De-Energized
Rev 0
38
 