DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

HCF40110BC1 View Datasheet(PDF) - STMicroelectronics

Part Name
Description
Manufacturer
HCF40110BC1
ST-Microelectronics
STMicroelectronics ST-Microelectronics
HCF40110BC1 Datasheet PDF : 11 Pages
1 2 3 4 5 6 7 8 9 10
HCC40110B
HCF40110B
DECADE UP-DOWN COUNTER/DECODER/LATCH/DRIVER
. SEPARATE CLOCK-UP AND CLOCK-DOWN
LINES
. CAPABLE OF DRIVING COMMON CATHODE
LEDS AND OTHER DISPLAYS DIRECTLY
. ALLOWS CASCADING WITHOUT ANY EX-
TERNAL CIRCUITRY
. MAXIMUM INPUT CURRENT OF 1 µA AT 18 V
(full package-temperature range)
. QUIESCENT CURRENT AT 20 V FOR HCC DE-
VICE
. 5 V, 10 V AND 15 V PARAMETRIC RATINGS
. INPUT CURRENT OF 100 nA AT 18 V AND
25 °C FOR HCC DEVICE
. 100 % TESTED FOR QUIESCENT CURRENT
. MEETS ALL REQUIREMENTS OF JEDECTEN-
TATIVE STANDARD No. 13 A, ”STANDARD
SPECIFICATIONS FOR DESCRIPTION OF ”B”
SERIES CMOS DEVICES”
EY
(Plastic Package)
F
(Ceramic Package)
C1
(Chip Carrier)
DESCRIPTION
The HCC 40110B (extended temperature range)
and HCF 40110B (intermediate temperature range)
are monolithic integrated circuits, available in 16-
lead dual in-line plastic or ceramic package. The
HCC/HCF 40110B is a dual-clocked up/down
counter with a special preconditioning circuit that
allows the counter to be clocked, via positive going
inputs, up or down regardless of that state or timing
(within 100 ns typ.) of the other clock line. The clock
signal is fed into the control logic and Johnson
counter after is preconditioned. The outputs of the
Johnson counter (which include antilock gating to
avoid being locked at an illegal state) are fed into a
latch. This data can be fed directly to the decoder
through the latch or can be strobed to hold a particu-
lar count while the Johnson counter continues to be
clocked. The decoder feeds a seven-segment bipo-
lar output driver which can source up to 25 mA to
drive LEDs and other displays such as low-voltage
fluorescent and incandescent lamps. A short dura-
tion negative-going pulse appears on the BORROW
output when the count changes from 0 to 9 or the
CARRY output when the count changes from 9 to
0. At the other times the BORROW and CARRY out-
put are a logic 1. The CARRY and BORROW out-
puts can be tied directly to the clock-up and
clock-down lines respectively of another HCC/HCF
40110B for easy cascading of several counters.
ORDER CODES :
HCC40110BF
HCF40110BEY
HCF40110BC1
PIN CONNECTIONS
September 1988
1/11
 

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]