75W, DUAL OUTPUT, MIXED-VOLTAGE DC/DC CONVERTERS
BCP Models
If the Sync pin detects the appropriate input signal, it will congure itself as a
slave; if no signal is detected, it will generate master Sync pulses.
Synchronization of converters requires that the master switching frequency
exceed the slave frequency by a minimum of 60kHz.
At the start of each DC/DC converter switching cycle, an internally generated
200-450ns pulse will be present at the Sync pin. If, however, the unit
receives an external Sync pulse, the DC/DC converters switching cycle will
be terminated and a new cycle initiated. Since the master frequency is higher
than the slave switching frequency, the slave cycles are always terminated
prematurely, thereby never allowing internal Synch pulses to be generated.
The external signals rising edge initiates the slave Sync process. External
signals must adhere to min./ max. limits stated in Performance/Functional
Specications.
Operating the BCP series DC/DC converters at higher switching frequencies
via the external Sync function will result in a slight degradation of efciency.
Contact DATEL for further information.
Output Overvoltage Protection
Each voltage output of the BCP Series converter is independently monitored
via an auxiliary winding in the output inductor. If the output voltage
should rise to a level which could be damaging to the load circuitry (see
Performance/Functional Specications for limits), the overvoltage circuitry will
power down the PWM controller and latch off the DC/DC converter. The
device must now be restarted by powering cycling VIN.
Current Limiting
When output current demands exceed the maximum output current rating by
107% to 133%, the DC/DC converter will go into a current limiting mode.
In this condition the output voltage decreases proportionately as the output
current increases, thereby maintaining a somewhat constant power dissipa-
tionreferred to as Power Limiting (see Figure 2). As the load approaches a
short circuit, the output current will continue to increase until it reaches the
rated Short Circuit Current limit.
BCP-5/15-3.3/15-D24, D48 Current Limiting Characteristics
(Nominal VIN)
6.00
5.00
5V Output
4.00
3.00
2.00
3.3V Output
1.00
0
Output Current, IOUT (Amps)
Figure 2. Current Limiting Characteristics
Short Circuit Condition
As described under "Current Limiting," when the BCP Series DC/DC con-
verter output is subjected to a short circuit condition, the output current will
remain at the Short Circuit Current limit. In this state there is negligible power
dissipated in the load. Therefore, most of the input power is dissipated within
the converter, causing the internal temperature to increase. If this condition
persists, Thermal Shutdown will activate and shutdown the DC/DC converter.
When the internal temperature is sufciently decreased, the converter will
self-start.
Thermal Shutdown
The BCP Series is equipped with Thermal Shutdown circuitry. If the internal
temperature of the DC/DC converter rises above the designed operating
temperature, a precision temperature sensor will power down the unit. When
the internal temperature decreases below the threshold of the temperature
sensor the unit will self-start.
Input Reverse-Polarity Protection
Upon applying a reverse-polarity voltage to the DC/DC converter, an internal
diode will be forward biased and draw excessive current from the power
source. Therefore, it is required that the input current be limited be either an
appropriately rated input fuse or a current limited power source.
Heat Sinks for BCP Series
DATEL offers two standard heat sinks that can be mounted to the half-brick
package to extend the converter's operating temperature range. Along with
the standard 2.3" x 2.4" x 0.5" (HS-CP) heat sink, DATEL has designed
a low-prole heat sink for height-restricted applications. This new heat sink
(HS-CPLP2) is designed with radiant ns that extend 0.51" beyond either
side of the 2.4" dimension of the BCP package. The convenience of this
design is that the nned extensions protrude only 0.31" below the top surface
of the DC/DC converter, allowing components with a prole height less than
0.215" to be mounted on the pc board below the heat sink. Therefore, while
the surface area of the low-prole heat sink measures 2.3" x 3.5", pcb real
estate is unaffected.
For optimum thermal performance in a natural convection application, the
low-prole heat sink should be mounted with the ns vertically oriented. Both
models are shipped with 0.009" sellf-adhesive thermal pad and mounting
screws.
6
5
4
HS-CPLP2
3
2
HS-CP
1
0
0
100
200
300
400
500
600
700
AIR VELOCITY (FT./MIN.)
HS-CP and HS-CPLP2 Heat Sink Performance Vs. Air Flow
(@ 10.5 Watts Power Dissipation)