AWS5506
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ranges
PARAMETER
MIN MAX UNIT
RF Input Power
> 500 MHz, 0/+7 V Control
-
2
W
Control Voltage
-0.2
+8
V
Operating Temperature
-40 +125 °C
Storage Temperature
-50 +150 °C
Θ JC
-
25 ° C/W
Stresses in excess of the absolute ratings may cause
permanent damage. Functional operation is not implied under
these conditions. Exposure to absolute ratings for extended
periods of time may adversely affect reliability. (8 pt bold)
PARAMETER
Table 3: Operating Ranges at 25° C (0, +3V)
CONDITION
FREQUENCY MIN TYP MAX UNIT
Switching Characteritics 5
Rise, Fall (10/90% or 90/10% RF)
-
On, Off (50% CTL to 90%/10% RF)
-
Video Feedthru
-
-
10
-
ns
-
20
-
ns
-
25
-
mV
Intermodulation Intercept Point (IP3) For Two-tone Input Power +10 dBm 0.5 - 2.0 GHz -
+45
-
dBm
Input Power for 1dB Compression
@ +3V
@ +5V
0.5 - 2.0 GHz
0.5 - 2.0 GHz
-
+21
+28
-
dBm
Control Voltage
VLOW = 0 to 0.2 V @ 20 uA Max
VHIGH = +3 V @ 100 uA Max to +5 V @ 200 uA Max
VS = VHIGH + 0.2V
The device may be operated safely over these conditions; however, parametric performance is guaranteed
only over the conditions defined in the electrical specifications.
Notes:
1. All measurements made in a 50 ohm system, unless otherwise specified.
2. DC = 300 kHz.
3. Insertion loss changes by 0.003 dB/°C.
4. Insertion loss state.
5. Video feedthru measured with 1 ns rise time pulse and 500 MHz bandwidth.
2
Data Sheet - Rev 2.1
08/2001