AD7853/AD7853L
TIMING SPECIFICATIONS1
(AVDD = DVDD = +3.0 V to +5.5
TMAX, unless otherwise noted)
V;
fCLKIN
=
4
MHz
for
AD7853
and
1.8/1
MHz
for
AD7853L;
TA
=
TMIN
to
Limit at TMIN, TMAX
(A, B Versions)
Parameter 5 V
3V
Units
Description
fCLKIN2
fSCLK3
t14
t2
tCONVERT
t3
t4
t55
t5A5
t65
t7
t8
t96
t106
t11
t11A
t127
t13
t148
t15
t16
tCAL9
tCAL19
tCAL29
500
4
1.8
1
4
fCLKIN
100
50
4.6
10 (18)
–0.4 tSCLK
ϯ0.4 tSCLK
0.6 tSCLK
50
50
75
40
20
0.4 tSCLK
0.4 tSCLK
30
30/0.4 tSCLK
50
50
90
50
2.5 tCLKIN
2.5 tCLKIN
31.25
27.78
3.47
500
4
1.8
1
4
fCLKIN
100
90
4.6
10 (18)
–0.4 tSCLK
ϯ0.4 tSCLK
0.6 tSCLK
90
90
115
60
30
0.4 tSCLK
0.4 tSCLK
50
50/0.4 tSCLK
50
50
130
90
2.5 tCLKIN
2.5 tCLKIN
31.25
kHz min
MHz max
MHz max
MHz max
MHz max
MHz max
ns min
ns max
µs max
µs max
ns min
ns min/max
ns min
ns max
ns max
ns max
ns min
ns min
ns min
ns min
ns min
ns min/max
ns max
ns max
ns max
ns max
ns max
ns max
ms typ
27.78
ms typ
3.47
ms typ
Master Clock Frequency
L Version, 0°C to +70°C, B Grade Only
L Version, –40°C to +85°C
Interface Modes 1, 2, 3 (External Serial Clock)
Interface Modes 4, 5 (Internal Serial Clock)
CONVST Pulsewidth
CONVSTto BUSYPropagation Delay
Conversion Time = 18 tCLKIN
L Version 1.8 (1) MHz CLKIN. Conversion Time = 18 tCLKIN
SYNCto SCLKSetup Time (Noncontinuous SCLK Input)
SYNCto SCLKSetup Time (Continuous SCLK Input)
SYNCto SCLKSetup Time. Interface Mode 4 Only
Delay from SYNCuntil DOUT 3-State Disabled
Delay from SYNCuntil DIN 3-State Disabled
Data Access Time After SCLK
Data Setup Time Prior to SCLK
Data Valid to SCLK Hold Time
SCLK High Pulsewidth (Interface Modes 4 and 5)
SCLK Low Pulsewidth (Interface Modes 4 and 5)
SCLKto SYNCHold Time (Noncontinuous SCLK)
(Continuous SCLK) Does Not Apply to Interface Mode 3
SCLKto SYNCHold Time
Delay from SYNCuntil DOUT 3-State Enabled
Delay from SCLKto DIN Being Configured as Output
Delay from SCLKto DIN Being Configured as Input
CALto BUSYDelay
CONVSTto BUSYDelay in Calibration Sequence
Full Self-Calibration Time, Master Clock Dependent
(125013 tCLKIN)
Internal DAC Plus System Full-Scale Cal Time, Master Clock
Dependent (111114 tCLKIN)
System Offset Calibration Time, Master Clock Dependent
(13899 tCLKIN)
NOTES
Descriptions that refer to SCLK(rising) or SCLK(falling) edges here are with the POLARITY pin HIGH. For the POLARITY pin LOW then the opposite edge of
SCLK will apply.
1Sample tested at +25°C to ensure compliance. All input signals are specified with tr = tf = 5 ns (10% to 90% of V DD) and timed from a voltage level of 1.6 V. See
Table X and timing diagrams for different interface modes and calibration.
2Mark/Space ratio for the master clock input is 40/60 to 60/40.
3For Interface Modes 1, 2, 3 the SCLK max frequency will be 4 MHz. For Interface Modes 4 and 5 the SCLK will be an output and the frequency will be f CLKIN.
4The CONVST pulsewidth will apply here only for normal operation. When the part is in power-down mode, a different CONVST pulsewidth will apply (see Power-
Down section).
5Measured with the load circuit of Figure 1 and defined as the time required for the output to cross 0.8 V or 2.4 V.
6For self-clocking mode (Interface Modes 4, 5) the nominal SCLK high and low times will be 0.5 t SCLK = 0.5 tCLKIN.
7t12 is derived form the measured time taken by the data outputs to change 0.5 V when loaded with the circuit of Figure 1. The measured number is then extrapolated
back to remove the effects of charging or discharging the 100 pF capacitor. This means that the time, t 12, quoted in the timing characteristics is the true bus relin-
quish time of the part and is independent of the bus loading.
8t14 is derived form the measured time taken by the data outputs to change 0.5 V when loaded with the circuit of Figure 1. The measured number is then extrapolated
back to remove the effects of charging or discharging the 100 pF capacitor. This means that the time quoted in the timing characteristics is the true delay of the part
in turning off the output drivers and configuring the DIN line as an input. Once this time has elapsed the user can drive the DIN line knowing that a bus conflict will
not occur.
9The typical time specified for the calibration times is for a master clock of 4 MHz. For the L version the calibration times will be longer than those quoted here due to
the 1.8/1 MHz master clock.
Specifications subject to change without notice.
–4–
REV. B
 

Share Link: 