IS42S16128
ISSI ®
Bank Active Command Interval
When the selected bank is precharged, the period trp has
elapsed and the bank has entered the idle state, the bank
can be activated by executing the active command. If the
other bank is in the idle state at that time, the active
command can be executed for that bank after the period
tRRD has elapsed. At that point both banks will be in the
active state. When a bank active command has been
executed, a precharge command must be executed for
that bank within the ACT to PRE command period (tRAS
max.). Also note that a precharge command cannot be
executed for an active bank before tRAS (min.) has elapsed.
After a bank active command has been executed and the
trcd period has elapsed, read write (including auto-
precharge) commands can be executed for that bank.
CLK
COMMAND ACT 0
tRRD
BANK ACTIVE (BANK 0)
ACT 1
BANK ACTIVE (BANK 1)
CLK
COMMAND ACT 0
tRCD
CAS latency = 3
BANK ACTIVE (BANK 0)
READ 0
BANK ACTIVE (BANK 0)
Clock Suspend
When the CKE pin is dropped from HIGH to LOW during
a read or write cycle, the IS42S16128 enters clock sus-
pend mode on the next CLK rising edge. This command
reduces the device power dissipation by stopping the
device internal clock. Clock suspend mode continues as
long as the CKE pin remains low. In this state, all inputs
other than CKE pin are invalid and no other commands
can be executed. Also, the device internal states are
maintained. When the CKE pin goes from LOW to HIGH,
clock suspend mode is terminated on the next CLK rising
edge and device operation resumes.
The next command cannot be executed until the recovery
period (tcka) has elapsed.
Since this command differs from the self-refresh command
described previously in that the refresh operation is not
performed automatically internally, the refresh operation
must be performed within the refresh period (tref). Thus the
maximum time that clock suspend mode can be held is just
under the refresh cycle time.
CLK
CKE
COMMAND READ 0
I/O
DOUT 0
DOUT 1
DOUT 2 DOUT 3
READ (BANK 0)
CAS latency = 2, burst length = 4
CLOCK SUSPEND
Integrated Silicon Solution, Inc. — 1-800-379-4774
33
Rev. A
03/13/00