DatasheetQ Logo
Electronic component search and free download site.
Transistors,MosFET ,Diode,Integrated circuits

IS42S16128 View Datasheet(PDF) - Integrated Silicon Solution

Part Name
Description
Manufacturer
IS42S16128 Datasheet PDF : 75 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
IS42S16128
ISSI ®
Self-Refresh Command
(CS, RAS, CAS, CKE = LOW, WE = HIGH)
This command executes the self-refresh operation. The
row address to be refreshed, the bank, and the refresh
interval are generated automatically internally during this
operation. The self-refresh operation is started by drop-
ping the CKE pin from HIGH to LOW. The self-refresh
operation continues as long as the CKE pin remains LOW
and there is no need for external control of any other pins.
The self-refresh operation is terminated by raising the
CKE pin from LOW to HIGH. The next command cannot
be executed until the device internal recovery period (tRC)
has elapsed. After the self-refresh, since it is impossible
to determine the address of the last row to be refreshed,
an auto-refresh should immediately be performed for all
addresses (1024 cycles).
Both banks must be placed in the idle state before
executing this command.
Burst Stop Command
(CS, WE, = LOW, RAS, CAS = HIGH)
The command forcibly terminates burst read and write
operations. When this command is executed during a
burst read operation, data output stops after the CAS
latency period has elapsed.
No Operation
(CS, = LOW, RAS, CAS, WE = HIGH)
This command has no effect on the device.
Device Deselect Command
(CS = HIGH)
This command does not select the device for an object of
operation. In other words, it performs no operation with
respect to the device.
Power-Down Command
(CKE = LOW)
When both banks are in the idle (inactive) state, or when
at least one of the banks is not in the idle (inactive) state,
this command can be used to suppress device power
dissipation by reducing device internal operations to the
absolute minimum. Power-down mode is started by drop-
ping the CKE pin from HIGH to LOW. Power-down mode
continues as long as the CKE pin is held low.
Power-Down Command (cont.)
All pins other than the CKE pin are invalid and none of the
other commands can be executed in this mode. The
power-down operation is terminated by raising the CKE
pin from LOW to HIGH. The next command cannot be
executed until the recovery period (tCKA) has elapsed.
Since this command differs from the self-refresh com-
mand described above in that the refresh operation is not
performed automatically internally, the refresh operation
must be performed within the refresh period (tREF). Thus
the maximum time that power-down mode can be held is
just under the refresh cycle time.
Clock Suspend
(CKE = LOW)
This command can be used to stop the device internal
clock temporarily during a read or write cycle. Clock
suspend mode is started by dropping the CKE pin from
HIGH to LOW. Clock suspend mode continues as long as
the CKE pin is held LOW. All input pins other than the CKE
pin are invalid and none of the other commands can be
executed in this mode. Also note that the device internal
state is maintained. Clock suspend mode is terminated by
raising the CKE pin from LOW to HIGH, at which point
device operation restarts. The next command cannot be
executed until the recovery period (tCKA) has elapsed.
Since this command differs from the self-refresh com-
mand described above in that the refresh operation is not
performed automatically internally, the refresh operation
must be performed within the refresh period (tREF). Thus
the maximum time that clock suspend mode can be held
is just under the refresh cycle time.
Integrated Silicon Solution, Inc. — 1-800-379-4774
11
Rev. A
03/13/00
 

Share Link: 